181
UF-5500 / 4500
11.2.17. High Voltage Section
1. Main
TRA (-) BIAS
Check the HVPS unit failure.
Check the voltage of
pin8 of HVPS unit.
Is +24V power
output?
Check the Main Board.
Check the SW1.
NO
YES
All of the outputs
are abnormal.
CHG BIAS ,
GRID
DEV BIAS
Replace the unit.
NO
Is it normal?
Replace the SW1.
Check the value of
the resistor F1.
YES
NO
Is the value of
the resistor 0
?
Replace the F1.
Make sure each output.
If any trouble is found, refer to
the manual for each part.
YES