11.2. Troubleshooting Details
11.2.1. Initialization
There are two types of initialization, one is the short initialization (about 3 seconds) and the other is the long initialization (about
10 seconds). The short initialization makes the unit enter the standby mode. The long initialization makes the unit enter the
standby mode after cleaning or detecting the rest of toner.
Getting to the Initialization Flowing Chart
YES
OK?
NO
Is it the initialization
after PAPER JAM?
NO
YES
The top cover is closed while the power is ON
or
the power is turned ON while the top cover is closed.
Isn't the registration sensor or
Exit sensor turned ON?
Has DRUM UNIT been set?
"
INFO CODE=007
"
is displayed.
YES
OK?
NO
Initialization (SHORT)
Standby mode
Standby mode
Is it the initialization
during TONER LOW?
NO
YES
Is it
the initialization after
removing DRUM
UNIT?
NO
YES
Initialization (LONG)
Isn't the unit TONER LOW?
"
INFO CODE=045
"
is displayed.
YES
OK?
NO
"
INFO CODE=041
"
is displayed.
Summary of Contents for UF-4500
Page 180: ...180 UF 5500 4500 ...
Page 248: ...248 UF 5500 4500 13 5 Test Chart 13 5 1 ITU T No 1 Test Chart ...
Page 249: ...249 UF 5500 4500 13 5 2 ITU T No 2 Test Chart ...
Page 281: ...281 UF 5500 4500 10 10 11 15 12 17 18 19 20 21 22 23 24 28 29 30 27 25 26 21 13 14 16 30 ...
Page 287: ...287 UF 5500 4500 130 131 132 133 134 135 136 137 138 139 140 141 PCB2 A UF 5500 only CN1 ...
Page 297: ...297 UF 5500 4500 ...
Page 305: ...305 UF 5500 4500 ...
Page 311: ...311 UF 5500 4500 501 502 503 504 506 507 505 508 509 511 510 514 513 512 P51 P53 P54 A51 P52 ...
Page 362: ...362 UF 5500 4500 ...