background image

1 Safety Precautions

1.1. General Guide Lines

 1. It is advisable to insert an isolation transformer in the AC supply before servicing this hot chassis.
 2. When servicing, observe the original lead dress, especially the lead dress in the high voltage circuits. If a short circuit is found,

replace all parts which have been overheated or damaged by the short circuit.

 3. After servicing, see to it that all the protective devices such as insulation barriers, insulation papers, shields and isolation R-C

combinations, are properly installed.

 4. When the receiver is not to be used for a long period of time, unplug the power cord from the AC cord outlet.
 5. Potential, as high as

29.0kV

is present when this receiver is in operation. Operation of the receiver without the rear cover

involves the danger of a shock hazard from the receiver power supply. Servicing should not be attempted by anyone who is not
thoroughly familiar with the precautions necessary when working on high voltage equipment. Always discharge the anode of the
picture tube to the receiver chassis before handling the tube. After servicing make the following leakage current checks to
prevent the customer from being exposed to shock hazards.

1.2. Leakage Current Cold Check

 1. Unplug the AC cord and connect a jumper between the two prongs on the plug.
 2. Turn on the receiver’s power switch.

Measure the resistance value, with an ohmmeter, between the jumper AC plug and each exposed metallic cabinet part on the
receiver, such as screw heads, aerials, connectors, control shafts, etc. When the exposed metallic part has a return path to the
chassis, the reading should be between 4 M

and 20 M

. When the exposed metal does not have a return path to the chassis,

the reading must be infinite.

1.3. Leakage Current Hot Check (Fig. 1)

 1. Plug the AC cord directly into the AC outlet. Do not use an isolation transformer for this check.
 2. Check a 2 k

non-inductive resistor and an AC/DC current meter, in series with each exposed metallic part on the receiver in

turn and an earth such as a water pipe.
The current from any point should not exceed 0.7 mA peak AC or 2 mA DC. In the case of a measurement being outside of
these limits specified, there is a possibility of a shock hazard and the receiver should be repaired and rechecked before it is
returned to the customer.

Fig. 1

1.4. X-Radiation

Warning:

The potential sources of X-Radiation in TV set are the EHT section and the picture tube. When using a picture tube test jig for
service, ensure that jig is capable of handling

29.0kV

without causing X-Radiation.

Note:

It is important to use an accurate periodically calibrated high voltage meter.

 1. Set the brightness to minimum.
 2. Use the remocon to get into Service Mode.
 3. Measure the EHT. The meter reading should indicate

27.5±1.5kV

. If the meter indication is out of tolerance, immediate service

and correction is required to prevent the possibility of premature component failure.

 4. To prevent the possibility X-Radiation, it is essential to use the specified picture tube, if service replacement becomes

necessary.

3

TX-21FX20RSF-IRAN

Summary of Contents for TX-21FX20RSF-IRAN

Page 1: ...2006 Matsushita Electric Industrial Co Ltd All rights reserved Unauthorized copying and distribution is a violation of law TX 21FX20RSF IRAN GP41 Chassis Audio Terminal AV 1 2 YUV MONITOR OUT RAV In V...

Page 2: ...e Hints 5 2 1 Service Position for E Board 5 2 2 Factory Mode Adjustment 5 2 3 Adjustment for White Balance 7 2 4 Adjustment for CRT CUT OFF 7 2 5 Adjustment Procedure 8 2 6 Adjustment 9 3 Conductor V...

Page 3: ...metallic cabinet part on the receiver such as screw heads aerials connectors control shafts etc When the exposed metallic part has a return path to the chassis the reading should be between 4 M and 2...

Page 4: ...WITCH G GEOMAGNETIC WOOFER AMP IC2401 PVP IC1801 R G B SCL SDA CVBS IN REAR INPUTS AV1 V L R AV 3 YUV V L R VCT IF IC601 V_IN CVBS OUT MON_OUT R G B R G B MON_OUT V L R EEPROM IC1101 VM SCL SDA A_IN I...

Page 5: ...ry Mode Adjustment 1 Factory Mode Adjustment a Set timer ON b Press remote s RECALL and panel s volume down key simultaneously to enter SERVICE 1 2 To Set Self Check Press the volume down button on TV...

Page 6: ...NOTE Service mode 2 options bit 6 Service Mode 3 Controls To enter SERVICE 3 press channel key 1 in SERVICE 2 entry screen 7 Service Mode 3 Function 6 TX 21FX20RSF IRAN...

Page 7: ...so that X 0 245 0 015 nit 3 Adjustment G CUT OFF so that Y 0 274 0 015 nit Adjustment of High Light 1 Adjustment Sub Bright so that Y 150 nit 2 Adjustment R Drive so that X 0 261 0 015 nit 3 Adjustmen...

Page 8: ...A 16 141 2V TPA 17 8 2 0 5V TPA 18 1 9 0 2V TPA 19 5 2 0 2V TPA 20 175 15V 2 5 2 High Voltage Item preparation 1 Receive the crosshatch pattern 2 Set to 0 Beam Screen VR minimum Contrast minimum Adjus...

Page 9: ...d Fig 21 10 Re adjust the Low Light controls to their correct settings and make sure that a uniform white field is obtained 11 Tighten the clamp screw A in Fig 10 Convergence 1 Apply a crosshatch patt...

Page 10: ...arily Fig 1 Purity magnet Set purity magnet that 2 magnets are TOP POSITION VRS magnet Set purity magnet 2 magnets are HORIZONTAL POSITION 2 Adjustment a Receive that Cross Hatch pattern b Adjust V SH...

Page 11: ...d 3 shown in Fig 11 2 The wedges should be set 120 apart from each other 3 Be certain that three wedges are firmly fixed and the Deflection Yoke is tightly clamped in place Otherwise the Deflection Yo...

Page 12: ...3 Conductor Views 12 TX 21FX20RSF IRAN...

Page 13: ...4 Schematic Diagram 13 TX 21FX20RSF IRAN...

Page 14: ...14 TX 21FX20RSF IRAN...

Page 15: ...4 1 A Board 4 1 1 A Board 1 5 1A 2A 3A 4A 5A 6A 7A 8A 9A 15 TX 21FX20RSF IRAN...

Page 16: ...4 1 2 A Board 2 5 1B 2B 3B 4B 5B 6B 7B 8B 9B 1A 2A 3A 4A 5A 6A 7A 8A 9A 16 TX 21FX20RSF IRAN...

Page 17: ...4 1 3 A Board 3 5 1B 2B 3B 4B 5B 6B 7B 8B 9B 1C 2C 3C 4C 5C 6C 7C 8C 17 TX 21FX20RSF IRAN...

Page 18: ...4 1 4 A Board 4 5 1C 2C 3C 4C 5C 6C 7C 8C 1D 2D 3D 4D 5D 6D 7D 9D 8D 18 TX 21FX20RSF IRAN...

Page 19: ...4 1 5 A Board 5 5 1D 2D 3D 4D 5D 6D 7D 9D 8D 19 TX 21FX20RSF IRAN...

Page 20: ...4 2 L Board 4 2 1 L Board 1 3 1A 2A 3A 20 TX 21FX20RSF IRAN...

Page 21: ...4 2 2 L Board 2 3 1A 2A 3A 1B 2B 3B 4B 5B 6B 7B 8B 9B 21 TX 21FX20RSF IRAN...

Page 22: ...4 2 3 L Board 3 3 1B 2B 3B 4B 5B 6B 7B 8B 9B 22 TX 21FX20RSF IRAN...

Page 23: ...5 Parts Locations 23 TX 21FX20RSF IRAN...

Page 24: ...6 Replacement Parts List 24 TX 21FX20RSF IRAN...

Page 25: ...tion Remarks C3046 ECJ2VC1H222J C 2200PF J 50V C305 F2A1C471A339 E 470UF 16V C306 D0GB240JA008 F 24 J 1 16V C307 D0GB240JA008 F 24 J 1 16V C308 D0GB240JA008 F 24 J 1 16V C3176 F2A1C101A310 E 100UF 16V...

Page 26: ...DIODE D366 B0AACK000004 DIODE D367 B0AACK000004 DIODE D402 B0HAJL000003 DIODE D503 B0AACK000004 DIODE D504 B0AACK000004 DIODE D507 B0ACMJ000001 DIODE D511 MA4108J DIODE D512 B0HAJL000003 DIODE D513 B...

Page 27: ...on Remarks R1201 ERJ3GEYJ102 M 1KOHM J 1 16W R1202 ERJ3GEYJ102 M 1KOHM J 1 16W R1228 ERJ3GEYJ101 M 100OHM J 1 16W R1229 ERJ3GEYJ101 M 100OHM J 1 16W R2112 ERJ3GEYJ102 M 1KOHM J 1 16W R2114 ERJ3GEYJ104...

Page 28: ...R664 ERDS2T0T C 0OHM 1 4W R665 ERDS2T0T C 0OHM 1 4W R669 ERDS2T0T C 0OHM 1 4W R670 ERJ3GEYJ101 M 100OHM J 1 16W R671 ERJ3GEYJ101 M 100OHM J 1 16W Ref No Part No Part Name Description Remarks R701 ERJ...

Page 29: ...0OHM J 1 16W JS634 ERJ3GEY0R00 M 0OHM J 1 16W JS670 ERJ3GEY0R00 M 0OHM J 1 16W L2 K1KA13A00140 CONNECTOR L3 K1KA04AA0190 CONNECTOR LF835 ELF21V012S LINE FILTER RM1001 B3RAD0000120 REMOCON RECEIVER SC...

Reviews: