26
8.1.2.
Initialization Pulse Adjust
1. Input the White signal to plasma video input.
2. Set the picture controls as follows.
Picture menu : Vivid
Normal : Set
Aspect : Full
3. Connect Oscilloscope to TPSC1 (SC).
Check the voltage (T2) at 100
μ
s period on the down slop.
8.1.3.
P.C.B. (Printed Circuit Board) exchange
8.1.3.1.
Caution
1. To remove P.C.B., wait 1 minute after power was off for discharge from electrolysis capacitors.
8.1.3.2.
Quick adjustment after P.C.B. exchange
Adjust the following voltages with the multimeter.
*See the Panel label.
Caution:
Absolutely do not reduce Vsus below Ve not to damage the P.C.B.
Test point
Volume
Level
T2
TPSC1 (SC)
VR16601 (SC)
250 V ± 10 V
P.C.B.
Name
Test Point
Voltage
Volume
Remarks
P Board
Vsus
TPVSUS (SS)
Vsus ± 2V
VR251 (P)
*
SC Board
Vad
TPVAD (SC)
- 185V ± 2V
VR16600 (SC)
A Board
White balance and Sub brightness for NTSC, PAL, HD, PC and 625i signals
Summary of Contents for TC-P54V10 - Viera 54" Full HD 1080p
Page 16: ...16 6 4 No Picture ...
Page 27: ...27 8 1 4 Adjustment Volume Location 8 1 5 Test Point Location ...
Page 29: ...29 ...
Page 30: ...30 ...
Page 36: ...36 ...
Page 38: ...38 10 3 Wiring 2 ...
Page 39: ...39 10 4 Wiring 3 ...
Page 40: ...40 10 5 Wiring 4 ...
Page 41: ...41 10 6 Wiring 5 ...
Page 42: ...42 ...
Page 43: ...43 11 Schematic Diagram 11 1 Schematic Diagram Note ...
Page 84: ...84 A B C D E F G H I 1 2 3 4 5 6 P P 1 BOARD COMPONENT SIDE ETX2MM761MGN ...
Page 98: ...98 ...
Page 100: ...100 13 1 2 Packing 1 ...
Page 101: ...101 13 1 3 Mechanical Replacement Parts List ...
Page 104: ...104 Safety Ref No Part No Part Name Description Q ty Remarks 47 XZB7 5X9D05 POLY BAG SCREW 1 ...
Page 105: ...105 13 2 Electrical Replacement Parts List 13 2 1 Replacement Parts List Notes ...