- 16 -
TC-20KL05P
ADJUSTMENTS
ITEM / PREPARATION
PROCEDURE
11- WHITE QUALITY CALIBRATION
PREPARATION:
1. Adjust the HELMHOLTZ device to local magnetic field. Ho-
rizontal: 0 ± 0.003 x 10
-4
T
2. Receive a white purity pattern.
3. Adjust CONTRAST and BRIGHT controls to maximum.
4. Previously adjust the CONVERGENCE.
5. Fully degauss the CRT by using an external degaussing
coil.
CALIBRATION:
1. Adjust the magnetic field in 0.4x10-4T (400 mG), and
check the white quality with the CRT turned to EAST and
to WEST.
2. Receive a red pattern, adjust the COLOR control to
maximum and confirm the purity adjustment.
3. If purity error is found at the CRT corners, apply magnetic
tapes to correct it, fully degauss the CRT again and repeat
the steps 1 and 2. Don't use this magnetic tapes on the
internal side of the yoke.
4. When magnetic tapes be used, fully degauss the face of
CRT (in a horizontal magnetic field = 0 ± 0.03x10-4T),
and repeat the items 1 and 2.
5. Adjust the control of COLOR to MINIMUM, and repeating
the item 1.
12- CONVERGENCE CALIBRATION
1. Adjust the HELMHOLTZ device to local magnetic field.
2.
Receive a crosshatch pattern
.
3. Adjust IMAGE menu to DINÂMIC NORMAL and the DAC
BRIGHT control for the crosshatch pattern to be gray.
4.
Remove the DY wedges and slightly tilt the deflection
yoke to the vertically and horizontally to obtain the good
overall convergence.
5. If purity error is found, repeat “Color Purity” adjustment
CALIBRATION
Static convergence calibration
l) Assure that the magnets are positioned according to
illustration 1.
ll) Adjust the 4 poles magnets to align the R and B
CENTRAL DOTS and adjust the 6 poles magnets to
align both DOTS with G.
lll) After adjustment above, assure that the magnets are
sealed, through the application of white glue.
Note:
The electron beams are moved rotationally when the
static convergence magnets are rotated.
The reduction of rotational beams differ depending of
the two magnets angle. Therefore, it is necessary to
repeat the magnets calibrations sometimes, until
obtaining a good alignment.
13- CRT CUT OFF CALIBRATION
1. Supply a WINDOWS signal.
2. Position DACs with the data below:
BRT
—> 50H
S-BRT
—> 31H
RGB CONTRAST
—> 02DAC
SUB-CONTRAST
—> 21H
R,G,B DRIVE
—> 31H
R,G CUT
—> 31H
CALIBRATION:
1. Press “5” (AKB OFF) and confirm that OSD becomes
blue.
2. Connect the oscilloscope in TPL5 and adjust BRT to
obtain 130V as in the Fig. 1 below.
3. Adjust the SCREEN to obtain a horizontal fine line in the
screen center.
4. Press “5” (AKB ON) and confirm that OSD becomes
white.
4 poles magnets (R-B)
6 poles magnets (R-G-B)
Fig. 1
Summary of Contents for TC-20KL05P
Page 18: ... 18 TC 20KL05P SCHEMATICS DIAGRAMS CRT P C B ...
Page 19: ...TC 20KL05P P C B SHEMATIC DIAGRAM TC 20KL05P 19 ...
Page 22: ... 22 TC 20KL05P Pino 42 Pino 55 IC601 Pino 18 Pino 19 Pino 38 Pino 40 ...
Page 23: ... 23 TC 20KL05P Pino 64 IC601 Pino 56 Pino 57 Pino 58 Pino 63 ...
Page 24: ... 24 TC 20KL05P Pino 1 IC801 Base Q501 Coletor Coletor Q551 Emissor Q601 Coletor Q602 ...