Default Value
N
PERIODIC_INFORM_INTERVAL
Value Format
INTEGER
Description
Specifies the interval length, in seconds, when the CPE must attempt
to connect with the ACS and call the Inform method.
Note
•
This setting is available only when
"
PERIODIC_INFORM_ENABLE
" is set to "
Y
".
Value Range
30–2419200
Default Value
86400
PERIODIC_INFORM_TIME
Value Format
STRING
Description
Specifies the time (UTC) to determine when the CPE will initiate the
periodic Inform method calls.
Note
•
Each Inform call must occur at this reference time plus or
minus an integer multiple of the
"
PERIODIC_INFORM_INTERVAL
". This
"
PERIODIC_INFORM_TIME
" parameter is used only to set the
"phase" of the periodic Informs. The actual value can be
arbitrarily set far into the past or future.
For example, if "
PERIODIC_INFORM_INTERVAL
" is set to
86400 (one day) and if "
PERIODIC_INFORM_TIME
" is set to
midnight on a certain day, then periodic Informs will occur
every day at midnight, starting from the set date.
•
If the time is set to "unknown time", the start time depends on
the CPE’s settings. However, the
"
PERIODIC_INFORM_INTERVAL
" must still be adhered to.
If absolute time is not available to the CPE, its periodic Inform
behavior must be the same as if the
"
PERIODIC_INFORM_TIME
" parameter was set to the
"unknown time".
•
Time zones other than UTC are not supported.
Value Range
4–32 characters
date and time format
Default Value
0001-01-01T00:00:00Z
CON_REQ_USER_ID
Value Format
STRING
Description
Specifies the user name used to authenticate an ACS making a
Connection Request to the CPE.
Value Range
Max. 256 characters
5.3.9 TR-069 Settings
228
Administrator Guide
Document Version: 2017-07