background image

Installation Guide

 

Thank you for purchasing our product.

 

This document provides important information about safe and proper 
operations of this Switching Hub.

 

Please read the 

"Important Safety Instructions" on pages from 3 to 5

.

 

Any problems or damage resulting from disassembly of this Switching Hub 
by customers are not covered by the warranty.

I0716-10719    Printed in Japan

Switch-M1

Model No. 

PN28168-TH

PN28168-MY

PN28168-ID

PN28168-SG

2-12-7, Higashi-Shimbashi, Minato-ku, Tokyo Japan, 105-0021
©

2019

Summary of Contents for Switch-M16eGLPWR+ Series

Page 1: ...ng Hub Please read the Important Safety Instructions on pages from 3 to 5 Any problems or damage resulting from disassembly of this Switching Hub by customers are not covered by the warranty I0716 10719 Printed in Japan Switch M16eGLPWR Model No PN28168 TH PN28168 MY PN28168 ID PN28168 SG 2 12 7 Higashi Shimbashi Minato ku Tokyo Japan 105 0021 2019 ...

Page 2: ... Outline 1 1 Features 1 2 Specifications 1 3 Accessories 1 4 Basic operation 2 Part Names and Functions 2 1 LED display change 2 2 PoE power supply function 3 Installation and Configuration 3 1 Mounting to rack 3 2 Configuration of IP address Basic Troubleshooting 3 6 7 7 8 9 9 10 13 14 15 15 16 18 ...

Page 3: ...as water in places with a lot of humidity in places with conductive dust or in places where there are corrosive and combustible gases Deviation could lead to fire electrical shock and or equipment failure Do not store or use the Switching Hub in places where it will be exposed to direct sunlight or high temperatures The temperature inside will rise which may cause fire Do not store or use the Swit...

Page 4: ... power cord if the STATUS LED blinks in orange system fault Deviation such as keeping connected for a long time could lead to fire Handle the Switching Hub carefully so that fingers or hands may not be damaged by twisted pair port SFP extension slot console port or power cord hook block CAUTION WARNING Do not connect any other devices except for 10BASE T 100BASE TX 1000BASE T devices to the twiste...

Page 5: ...Communications failures might be generated due to causes such as malfunctions or misoperations while the Switching Hub is being used When using this Switching Hub for applications which require extremely high reliability be careful to expend all possible means to ensure safety and reliability This Switching Hub was not designed nor manufactured with the intention that it be used for applications i...

Page 6: ...ion High humidity Possible spilled liquid water Dusty Possible static charge such as carpet Under direct sunlight Possible condensation High low temperature exceeding the specifications environment Strong vibration and or strong shock Please use this Switching Hub in place where ambient temperature is from 0 to 50 C Failure to satisfy the conditions above may result in a fire electric shock equipm...

Page 7: ...on changes and verifications of the Switching Hub Remotely configure the PoE settings for each port Ports 1 to 16 Equipped with energy efficient Ethernet EEE conforming to IEEE802 3az LPI When there is no data transmission at link up the energy saving state automatically starts so that power consumption can be reduced on each port Embedded power saving mode detects the connection status automatica...

Page 8: ... function Ports 1 to 16 support the IEEE802 3at compatible power supply function Maximum power supply 30 W per port 185 W in total Power supply method Alternative A Using signal line 1 2 3 6 Others IEEE802 1D spanning tree rapid spanning tree IEEE802 1X authentication function supported port base authentication Port monitoring ring protocol IGMP snooping loop detection shutoff function storm contr...

Page 9: ...sis POWER LED Power STATUS ECO LED Status ECO mode and TEMP LED Temperature sensor light in green and the Switching Hub starts operation as a Switching Hub As this Switching Hub succeeds in communicating with a terminal connected to each port LED of the port lights up When the terminal is not operating normally for example when power is not supplied to the terminal LED is not lighted Quantity For ...

Page 10: ...ge and Switching Hub can be connected to this port Install the device so that the length of twisted pair cable CAT5e or above becomes 100 m or less 10 100 1000BASE T port ports 17 18 Devices such as 10 100 1000BASE T terminal hub repeater bridge and Switching Hub can be connected to this port Install the device so that the length of twisted pair cable CAT5e or above becomes 100 m or less SFP exten...

Page 11: ...he total power supply of the Switching Hub is exceeding 185 W FAN LED Fan sensor Green Light System is operating normally Orange Blink Fan fault is occurring TEMP LED Temperature sensor Green Light The system is normally operating Orange Blink The temperature exceeded the set threshold of the internal temperature sensor Set threshold of the internal temperature sensor 65 C factory default LOOP HIS...

Page 12: ...d Green Blink Orange Light Off No terminal is connected or the ECO mode is set Port LED Right Green Light Orange Blink a single port Off connected Port LED Right Port LED Left Power is supplied normally Ports 1 to 16 only Overload power supply ports 1 to 16 only or overload in Power is not supplied or PoE receiving equipment is not Data is being sent received at 10 100 1000 Mbps Shut off by the lo...

Page 13: ...tting OFF ON by using a console cable for detail see the attached CD ROM The default setting is ON If you wish to clear loop detection history turn OFF once the power supply of the Switching Hub and turn it ON again Then loop detection history is deleted The Switching Hub can hold up to 64 loop history logs Two types of Base modes The mode at the start is called Base mode There are two types of Ba...

Page 14: ... 1 Some PoE powered devices may have a large difference in power consumption between their maximum power use condition and normal condition Carefully configure them so that the upper limit of power supply will not be exceeded 2 If you don t set a priority for power supply or if the same priority is given note that the power supply priority is assigned to the ports in ascending order of the port nu...

Page 15: ...r fixing the main unit and the mounting bracket and fix the brackets to the main unit by tightening screws into 4 holes located at the sides Then mount this Switching Hub firmly to the rack using the supplied 4 screws for 19 inch rack or screws furnished at the rack Installation and Configuration 3 ...

Page 16: ...select System I P Configuration The screen to enter some addresses is displayed Screen 4 5 Press I to set an IP Address press M to set a Subnet Mask or press G to set a Default Gateway Then enter the specified address Screen 4 6 After completing the settings select Q uit to previous menu twice to return to Main Menu Screen 2 Here select Save Configuration to F lash Screen 5 and the command prompt ...

Page 17: ...c Screen 1 Screen 3 Screen 2 Screen 4 Screen 5 For the following please see the PDF version Operating Instructions in CD ROM Detailed configuration and management methods using the CLI Configuration and management method from ZEQUO assist Plus ...

Page 18: ...gs The Port LED Right lights in orange Loop is occurring By removing the loop orange LED will be turned off LOOP HISTORY LED Blinks in orange This is to notify that there is a port in which a loop is occurring or has been removed within 3 days Communications are slow Are the communication speed and mode settings correct If the proper communication mode signal cannot be obtained apply half duplex m...

Page 19: ...h the IEEE802 3at 30W standard Port LED Right is blinking orange Ensure that the total power supply demand from PoE powered devices does not exceed 185 W When the power supply is suddenly shut off It is likely that a PoE powered device in use has a different power consumption in normal operation and standby states After turning on the PoE LED power supply mode confirm that a single port is not ove...

Reviews: