background image

<In case of Minus Common>

I/O CIRCUIT DIAGRAMS

4

Main Circuit

12 to 24V DC

±10%

+
-

Load

Load

Load

V

Output 1_1

Output 1_2

Output 2_1

Output 2_2

Output 3_1

Output 3_2

0V

Terminal No.

Internal circuit

Users’ circuit

*1

External input  

indicator 2 

External input  

indicator 1

External input 

circuit 2

External input 

circuit 1

External input 2

External input 1

Switching terminal of 

time-out function (IN) 

Switching terminal of 

time-out  function (+V) 

<In case of Plus Common>

12 to 24V DC

±10%

+
-

V

0V

Terminal No.

Main Circuit

Load

Load

Load

Output 1_1

Output 1_2

Output 2_1

Output 2_2

Output 3_1

Output 3_2

Internal circuit

Users’ circuit

External input 

indicator 2

External input 

circuit 2

External input  

indicator 1

External input 

circuit 1

External input 2

External input 1

*1

Switching terminal of 

time-out function (IN) 

Switching terminal of 

time-out function (+V) 

*1

Non-voltage contact or NPN open-collector transistor, PNP open-collector transistor

or

or

0 to 1V or 10V to +V: Valid (External input indicator lights up )

4 to 6V or Open: Invalid (External input indicator turns OFF)

<Bottom of the product (Unit: mm)>

M30 × 1.5

80

80

2. Make sure to fit a mounting packing (ac

-

cessory) to the terminal area of the main

body first, then put the main body into the

mounting plate.  (Note 1)

Main body

Mounting packing

(Accessory)

Mounting nut

(Accessory)

Mounting tool

SW-MT1

(Optional)

Mounting 

plate 

Notes: 1) Make sure to use the mounting packing (accessory), or waterproof property will be 

invalid.

2)  A mounting tool 

SW-MT1

 for fastening the mounting nut is available separately.

The shape of fastening part of 

SW-MT1

 is M10 nut.

3) When using the products for two-hand control, be sure to mount the products by 

complying with ISO 13851 (EN 574, JIS B 9712) and ANSI B11.1, B11.9.

 

In ad-

dition, be sure to use a controller for two-hand control which complies with ISO 

13851 (EN 574, JIS B 9712).

<Fitting diagram of the mounting packing> 

Mounting packing

(Accessory)

3. Fasten a mounting nut (accessory) from

the  reverse  side  of  the  mounting  plate.

(Note 2)

The tightening torque should be 2 to

3N·m.

FUNCTIONAL DESCRIPTION

2

1. Operation indicator

(Green)

1. Operation indicator

(Green)

3. Fault indicator

(Yellow)

2. Power indicator

(Green)

4. External input

indicator 1 

(Green)

5. External input

indicator 2

(Orange)

4. External input

indicator 1 

(Green)

5. External input

indicator 2

(Orange)

4. External input

indicator 1

(Green)

5. External

input 

indicator 2 

(Orange)

6. Sensing 

surface

8. B side terminal

block

7. A side terminal

block

Designation

Function

1

Operation indicator 

× 2 (Green)

Lights up when an object is detected.

2

Power indicator

(Green)

Lights up when the power is ON.

3

Fault indicator

(Yellow)

Blinks or lights up when fault occurs. 

Refer to “

TROUBLESHOOTING

” for details in blink

-

ing operation. 

4

External input indi-

cator 1 × 3 (Green)

Lights up when external input 1 is valid.

Refer to “

FUNCTIONS

” for details. 

5

External input indica-

tor 2 × 4 (Orange)

Lights up when external input 2 is valid.

Refer to “

FUNCTIONS

” for details.

6

Sensing surface

Thru-beam type photoelectric sensor is incorporated in the sensing 

surface. Thus, when the light beam is interrupted by fingers, the sensor 

goes into the beam interrupted condition and output turns ON or OFF.

7

A side terminal block

CoV, output 1, 2 and 0V.

8

B side terminal block Connects switching terminals of time-out function, output 

3, and external input 1, 2. 

● This product is an optical touch switch which detects a hand

by a thru-beam type photoelectric sensor.

● When a hand is touched to the sensing surface, output turns

ON or OFF.

OUTLINE

1

● Follow the procedures below when mounting this product on a mounting plate.

MOUNTING

3

1. Drill a hole in a mounting plate (thickness: 3mm or less.)

Procedures

Dimensions of a mounting hole 

to be drilled when mounting on 

a metal plate (Unit: mm)

Dimensions of a mounting hole 

to be drilled when mounting on 

a resin plate (Unit: mm)

4.8

+0.2

0

33

+0.5

0

ø30.5

+0.5

0

4.8

+0.2

0

ø30.5

+0.5

0

18.4

+0.5

0

33

+0.5

0

10.2

+0.5

0

R4±0.1

R4±0.1

WARNING

● Never use this product in a device for personnel protection.

 

● In case of using devices for personnel protection, use products which meet laws and standards,

such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country.

● Do not use this product as a device for emergency stop.

● This product is used to start up the machinery. Securing safety for the start-

up of machinery should be performed separately.

 

● When using the products for two-hand control, comply with the following contents.

•  Select a model of a control device for two-hand control, based on results of risk assessment.

• Make sure to use a controller for two-hand control which complies with

ISO 13851 (EN 574.)

•  For another requirements such as mounting of this product, or prevention of 

accidental actuation and of defeat etc., comply with ISO 13851 (EN 574, JIS 

B 9712) and ANSI B11.1, B11.9.  Furthermore, comply with the regulations es

-

tablished by national or regional security committees (Occupational Safety and 

Health Administration: OSHA, the European Standardization Committee, etc.) 

INSTRUCTION MANUAL

Optical Touch Switch

SW-101

MJE-SW101 No.0055-94V

Thank you very much for purchasing Panasonic products. Read this Instruction 

Manual carefully and thoroughly for the correct and optimum use of this product.  

Kindly keep this manual in a convenient place for quick reference.

Ramco National

www.PanasonicSensors.com

1-800-280-6933

Reviews: