Page 1-22
Check Every 560 Hours (Once a Week)
1-5-3
Cleaning and Lubricating the X-Y Table
This unit is for moving the board to the position for recognition or print.
1.
Remove the cover a and b.
∗
Cover a 4 bolts
∗
Cover b 4 bolts
∗
Remove the cover of X-axis sliding to the left
and right, and the cover of Y-axis to the front
and rear.
2.
Clean and lubricate the linear bearing
and ball screw.
[Oil : ALBANIA 2]
1.Y-axis linear bearing
Lubricate the sliding unit.
2.X-axis linear bearing
Lubricate the sliding unit.
3.Y-axis ball screw
Apply grease to the ball screw
4.X-axis ball screw
Apply grease to the ball screw.
3.
After lubricating, set the cover re-
moved at the procedure 1.
193C-E-MMA01-A05-00
Cover b
Cover a
193C-004E
X-axis linear bearing
Y-axis linear bearing
Y-axis ball screw
X-axis ball screw
0799C2AA