2-5-9-2 Wiring for Mixed Series and Parallel Connection
(Example of Control Category 4 Wiring)
This method is used to connect multiple emitters and receivers facing each other in a combina-
tion of parallel and series connections. This connection method is used when there are two or
more dangerous parts of the machine and two or more paths of approach. A total of up to 5 sets
can be connected in a combination of series and parallel connections, with a maximum of 5 sets
connected in series, or a maximum of 3 sets connected in parallel. Maximum total of 144 beam
channels. In a series connection, the control output (OSSD 1 / 2) turns OFF regardless of which
set is in the light-blocked state. In a parallel connection, the control output (OSSD 1 / 2) turns
OFF only on sets in the light-blocked state.
WARNING
●
To use a series connection, you must use the special-use
SFD-CSL
□ series connection cables
to connect emitters to emitters and receivers to receivers as shown on the following page. Risk
of death or serious injury if a non-sensing area is created due incorrect connection.
●
When connecting in parallel, connect the interference prevention wire of each receiver and its
paired emitter as shown on the following page. Risk of death or serious injury if a non-sensing
area is created due to incorrect connection.
●
Using line synchronization setting and 12-core cable
<Using PNP output>
Interlock function
Valid (manual reset)
External device monitor function Valid
Auxiliary output 1
Can be used
*Symbols
Switch S1
Vs to Vs − 2.5V (sink current 5mA or less): Emission halt (Note 1), Open: Emission
K1, K2: External device (forcible guide relay or magnetic conductor)
Notes: 1) Vs is the supply voltage.
2) For information on reset, refer to
“3-2 Interlock Function (8-core cable, 12-core cable)”
.
Summary of Contents for SF4D Series
Page 2: ... Panasonic Industrial Devices SUNX Co Ltd 2017 2 MEMO ...
Page 126: ...Functions Panasonic Industrial Devices SUNX Co Ltd 2017 126 MEMO ...
Page 130: ...Maintenance Panasonic Industrial Devices SUNX Co Ltd 2017 130 MEMO ...
Page 140: ...Troubleshooting Panasonic Industrial Devices SUNX Co Ltd 2017 140 MEMO ...
Page 174: ... Panasonic Industrial Devices SUNX Co Ltd 2017 174 MEMO ...