![Panasonic Section 700 Technical Manual Download Page 144](http://html1.mh-extra.com/html/panasonic/section-700/section-700_technical-manual_4137806144.webp)
144
ICX (International), issued March/1999
ICX-35-700
Chapter 5. Key Telephone Features
Section 700 - Operation
Hardware Requirements
•
Caller ID daughter circuit card on the Loop Start Trunk Card if a Loop Start Trunk receives the
call.
•
ISDN (PRI-T Point) if ISDN card receives the call.
•
Large Display Telephone or 44-Series Small Display Telephone.
Considerations
•
Caller ID is available ISDN PRI.
•
Caller ID circuit card must be installed and enabled. (See “Caller ID” on page 27).
•
Caller ID is typically 10 digits. If the local calling area requires 7-digit dialling, the call log
outdialling will not operate properly.
Camp-on (Call Waiting)
CPC-96, CPC-288, and CPC-576 All Versions
Description
If you dial a busy extension, you can camp onto that extension and send a Call Waiting signal to the
called party. The called party then needs only to replace the handset and pick it up again to be
automatically connected to the new call. The called party can also press the HOLD key to place the
first call on hold and then answer the waiting call.
The System provides two types of call waiting:
•
Automatic Call Waiting: You do not need to enter a code to send the Call Waiting signal to
the busy extension. You need only to remain on the line.
•
Manual Call Waiting: You must enter a code to send a Call Waiting signal to the busy
extension.
Beginning with CPC Version 3.0, you can leave a text message that displays on the busy phone. Any
one of the following messages can be selected. Messages 6 to 9 and 0 have no default message text.
3. Press the following keys to view the call log:
# - Move forward in call log
* - Move back in call log
NEXT - View the next 5 calls
PREV - View the previous 5 calls
4. To store the call log number in a personal speed dial:
Press the PROG key, the speed dial bin number (80-99)
and press the left Soft key (to dial the add digits, usually an
area code) and press the HOLD key.
OR...
Press the PROG key, the speed dial bin number (80-99)
and press the right Soft key and press the HOLD key.
Action
Result