CC-LINK Network Communication
WUME-SCHG1C-4
4-71
4-15 Other precautions
• For the
HG-T
series controllers, waveform values will be temporarily reset during measurement if
the following commands are written.
Command code
Name
Remarks
0x001E
BANK LOAD execution (LOAD)
―
0x0046
Average count (SPEED)
―
0x0047
Measurement direction (DIRECT)
―
0x0048
Alarm delay count (DELAY)
For write only
0x0059
Sampling cycle (SAMPLI)
For write only
0x0300
Operation mode (OP.MODE)
For write only
0x0304
Sensitivity setting
For write only
0x0305
Judgment level (JDG.LVL)
For write only
0x0306
Judgment filter (JDG.FIL)
For write only
0x030C
Stain check (STA.CHK)
For write only
0x030D
Stain threshold (STA.THR)
For write only
0x031E
Sensor head cumulative run time (HD.TIME)
―
0x0325
Reverse insertion check (DIR.CHK)
For write only
• For the
HG-T
series controllers, approximately five seconds after the power is turned ON, measured
values are synchronously collected from the heads connected to each controller.
Summary of Contents for SC-HG1-C
Page 2: ...WUME SCHG1C 4 2 MEMO ...
Page 8: ...WUME SCHG1C 4 8 MEMO ...
Page 16: ...WUME SCHG1C 4 1 8 MEMO ...
Page 17: ...2 1 2 System Configuration 2 1 Communication unit system 2 2 2 2 Unit types 2 4 ...
Page 22: ...WUME SCHG1C 4 2 6 MEMO ...
Page 106: ...WUME SCHG1C 4 4 72 MEMO ...
Page 107: ...5 1 5 Specifications 5 1 Specifications 5 2 5 2 Dimensions 5 3 ...
Page 110: ...WUME SCHG1C 4 5 4 MEMO ...
Page 111: ...6 1 6 Warranty 6 1 When you purchase and use the product 6 2 ...
Page 114: ...WUME SCHG1C 4 6 4 MEMO ...
Page 124: ...WUME SCHG1C 4 8 8 MEMO ...
Page 126: ... MEMO ...
Page 127: ... MEMO ...