17
6.2.
Self Diagnostic Function Error Code
6.2.1.
CD Mechanism Error Code Table
6.2.2.
Power Amp Error Code Table
Error Code
Diagnostic Contents
Description of error
Automatic FL Display
Remarks
CD H15
CD Open Abnormal
During operation
POS_SW_R On fail to be
detected with 4 sec. Error
No. shall be clear by force
or during cold start.
Press [ ] on main unit for
next error.
CD H16
CD Closing Abnormal
During operation
POS_SW_CEN On fail to
be detected with 4 sec.
Error No. shall be clear by
force or during cold start.
Press [ ] on main unit for
next error.
F26
Communication between
CD servo LSI and micro-p
abnormal.
During switch to CD func-
tion, if SENSE = “L” within
failsafe time of 20ms.
Press [ ] on main unit for
next error.
Error Code
Diagnostic Contents
Description of error
Automatic FL Display
Remarks
F61/F76
Power Amp IC output
abnormal
During power-on, PDET1,
PDET2 & MAINV_DET /
TEMP_DET is “L” after 1
sec.
Press [ ] on main unit for
next error.