6 Self Diagnosis Display Function
This unit is equipped with the self diagnosis display function, which alarms faulty operation with error code. Use this function during
servicing.
6.1. Automatically Displayed Error Codes
An error code automatically appears on the display (LCD) when faulty operation is detected. Refer to Fig. 6.1.
Fig. 6.1
6.2. Display Details
Refer to the following table.
LCD display
Symptom
Cause and Remedy
OVERLOAD
Speaker short, amplifier failure
Speaker short and failure in power
amplifier, pre-amplifier circuits. Check for
faulty parts and replace with new parts if
necessary.
Humidity protection activated
F70
Communication error between sub micro-
processor and its peripheral LSI
Failure sub-micro processor and its
peripherals LSI. Check for faulty parts and
replace with new parts if necessary.
F76
When the power is turned on, the unit
power automatically turns off; the power
cannot be turned on.
Failure in the power circuit system of the
unit. This may happen when the direct
current electricity is supplied to speaker
terminals. Check for the above and replace
with new parts if necessary.
6.3. Returning to Normal Display
Press the [POWER] button on the unit to exit the function. The power is turned off.
6.4. Overload/Shutdown Detection intenal Condition
It detects OVERLOAD, POWER MALFUNCTION with [THRM_DET], [SHORT_DET] and [DC_DET] input port. It detects the
following condition depending on the input of the port as below table.
(H: DC ± 5V / L: DC ± 0V)
PROT
Detection of malfunction
Display and operation
SHORT_DET
THRM_DET
DC_DET
H
L
H
Normal
-----
L
L
H
Speaker Short, Malfunction of Amplifier
[OVERLOAD] / POWER OFF
L
H
H
Detection of THERMAL PROTECTION
-
-
L
Detection of POWER MALFUNCTION
[ _ _ _ F76 _ _ _ ] / POWER OFF
6.5. Overload/Thermal Detection Display
When overload is detected, automatic POWER OFF will occur. But if any key on the remote control other than the [POWER] key
is pressed before that (including the [HELP] key), the scroll display will show [SWITCH_OFF_POWER]. Then, 1 second after
display of message, [OVERLOAD] will be shown on the scroll display.
6.6. Activating Self Diagnosis Function (Servicing Mode)
This mode can be used during servicing.
1. Plug the AC adapter to the power source. Press and hold down the [ENTER] button and the [SPEAKERS A] button, and then
press the [POWER] button at the same time.
19
SA-XR58E / SA-XR58EG
Summary of Contents for SA-XR58E
Page 9: ...5 Operating Instructions Procedures 5 1 Remote Control Operation 9 SA XR58E SA XR58EG ...
Page 10: ...5 2 Main Unit Operation 10 SA XR58E SA XR58EG ...
Page 11: ...5 3 Main Unit connections SA XR58 5 3 1 HDMI connection 11 SA XR58E SA XR58EG ...
Page 12: ...5 3 2 Video connection 12 SA XR58E SA XR58EG ...
Page 13: ...13 SA XR58E SA XR58EG ...
Page 14: ...5 3 3 Audio connection 14 SA XR58E SA XR58EG ...
Page 15: ...15 SA XR58E SA XR58EG ...
Page 16: ...5 3 4 Connection with other equipments 16 SA XR58E SA XR58EG ...
Page 17: ...5 3 5 Tuner Antenna Connection Power 17 SA XR58E SA XR58EG ...
Page 18: ...5 3 6 Headphone connection 18 SA XR58E SA XR58EG ...
Page 29: ...8 3 Main Parts Location Diagram 29 SA XR58E SA XR58EG ...
Page 58: ...SA XR58E SA XR58EG 58 ...
Page 68: ...68 SA XR58E SA XR58EG ...
Page 96: ...SA XR58E SA XR58EG 96 ...
Page 106: ...SA XR58E SA XR58EG 106 ...
Page 110: ...110 SA XR58E SA XR58EG ...
Page 111: ...17 Exploded Views 17 1 Cabinet Parts Location SA XR58E SA XR58EG 111 ...
Page 112: ...SA XR58E SA XR58EG 112 ...
Page 113: ...17 2 Packaging SA XR58E SA XR58EG 113 ...
Page 114: ...SA XR58E SA XR58EG 114 ...