3. Press
to close the tray.
4. Press “CD DIRECT PLAY (5)” and
wait until the tray is open.
5. Press
and remove the CD.
6. Press
to close the tray.
7. Press “
n
/STOP” to indicate Error Code.
·
If several problem exist, error code will change each time when “
n
/STOP” is pressed. (e.g. F15
→
F26
→
F16 ....etc).
11.5. To clear all Error code
1. Press
and hold button for 5 seconds.
2. FL indicator shows “CLEAR” for 1 second and change to “T”.
11.6. To exit from Self-Diagnostic function
1. Press
button on main unit or remote control.
11.7. Power Amplifier Failure (F61)
1. When power amplifier fail, F61 will indicate automatically.
11.8. Description of Error Code
11.8.1. Abnormality detection for Deck Mechanism block
No.
Abnormal Items
Error Display Method of Detection
1
MODE SW abnormal
H01
Normal operation during mecha transition, MODE SW abnormal is
memorized. The content of abnormality can be confirmed in the
abnormal detection mode explained in the later section.
2
REC INH SW abnormal
H02
The content of abnormality can be confirmed in the abnormal detection
mode explained in the later section.
3
HALF SW abnormal
H03
The content of abnormality can be confirmed in the abnormal detection
mode explained in the later section.
4
Reel pulse abnormal
F01
The content of abnormality can be confirmed in the abnormal detection
mode explained in the later section.
11.8.2. Abnormality detection for CD/Changer block
No.
Abnormal Items
Error Display Method of Detection
1
REST SW abnormal
F15
Under normal operation (Self-Diagnostic Mode inclusive), this error
occurs when the REST SW ON is not detected within the specified time
and shall be memorized.
2
Transmission error between CD servo
LSI and micon
F26
Under normal operation (Self-Diagnostic Mode inclusive), this error occurs
when the selection is set to CD and SENSE=’H’ is detected and
SENSE=’L’ is not detected within a fail safe time (20ms) after system
command transmission was sent.
3
CLAMP SW abnormal
F16
Refer to section 11.8.4 (Mechanism Error Code Table) [M-0A] error is
detected.
4
BOTTOM SW abnormal
F17
Refer to section 11.8.4 (Mechanism Error Code Table) [M-09] error is
detected.
5
POSITION SW abnormal
F27
Refer to section 11.8.4 (Mechanism Error Code Table) [M-05 ~ M-08] error
is detected.
6
SW1 abnormal
F28
Refer to section 11.8.4 (Mechanism Error Code Table) [M-02 ~ M-08] error
is detected.
7
SW2 abnormal
F29
Refer to section 11.8.4 (Mechanism Error Code Table) [M-02 ~ M-08] error
is detected.
8
OPEN SW abnormal
H15
Refer to section 11.8.4 (Mechanism Error Code Table) [M-01] error is
detected.
9
CLOSE SW abnormal
H16
Refer to section 11.8.4 (Mechanism Error Code Table) [M-01] error is
detected.
10
DISC SENSOR
F30
Refer to section 11.8.4 (Mechanism Error Code Table) [M-01] error is
detected.
42
SA-AK330GC / SA-AK330GN
Summary of Contents for SA-AK330GC
Page 9: ...8 Operation Procedures 9 SA AK330GC SA AK330GN ...
Page 10: ...10 SA AK330GC SA AK330GN ...
Page 55: ...15 Voltage Measurement 55 SA AK330GC SA AK330GN ...
Page 56: ...56 SA AK330GC SA AK330GN ...
Page 87: ...21 Troubleshooting Guide 87 SA AK330GC SA AK330GN ...
Page 89: ...22 1 Deck Mechanism RAA4502 S 22 1 1 Deck Mechanism Parts Location 89 SA AK330GC SA AK330GN ...
Page 90: ...90 SA AK330GC SA AK330GN ...
Page 93: ...93 SA AK330GC SA AK330GN ...
Page 95: ...22 3 1 Cabinet Parts Location 22 3 Cabinet 95 SA AK330GC SA AK330GN ...
Page 96: ...96 SA AK330GC SA AK330GN ...
Page 106: ...22 6 Packaging 106 SA AK330GC SA AK330GN PRT0411 P S J N A E ...