background image

Panasonic Corporation
1006 Kadoma, Kadoma City, Osaka, Japan

85464609100010

Save These Instructions!
Conserver ce mode d’emploi
Bewahren Sie bitte diese
Bedienungsanleitung auf.
Conservate queste istruzioni
Guarde estas instruções

Φυλάξτε τις οδηγίες αυτές

Guarde estas instrucciones

Model No.

Indoor Unit

Concealed-Duct High-Static Pressure

S-200PE1E8,  S-250PE1E8

Outdoor Unit

Heat Pump Unit (3-phase)

U-200PE1E8,  U-250PE1E8

Split System Air Conditioner

Climatiseur Split System

Split-System-Klimagerät

Condizionatore d’Aria Split 

Aparelho de Ar Condicionado Sistema Split

Κλι ατιστικ Δύο Μονάδων

Acondicionador de Aire de tipo Sistema Partido

• INSTRUCTION MANUAL

• MODE D’EMPLOI

• BEDIENUNGSANLEITUNG

• ISTRUZIONI PER L’USO

• MANUAL DE INSTRUÇÕES

• ΕΓΧΕΙΡΙΔΙΟ ΟΔΗΓΙΩΝ

• MANUAL DE INSTRUCCIONES

This air conditioner uses the new refrigerant R410A.

OI-85464609100010_COVER.fm  Page 2  Friday, February 4, 2011  3:23 PM

Summary of Contents for S-200PE1E8

Page 1: ...uct High Static Pressure S 200PE1E8 S 250PE1E8 Outdoor Unit Heat Pump Unit 3 phase U 200PE1E8 U 250PE1E8 Split System Air Conditioner Climatiseur Split System Split System Klimagerät Condizionatore d Aria Split Aparelho de Ar Condicionado Sistema Split Κλι ατιστικ Δύο Μονάδων Acondicionador de Aire de tipo Sistema Partido INSTRUCTION MANUAL MODE D EMPLOI BEDIENUNGSANLEITUNG ISTRUZIONI PER L USO MA...

Page 2: ...lems or questions concerning your Air Conditioner you will need the following information Model and serial numbers are on the nameplate on the bottom of the cabinet Model No ______________________ Serial No ____________________ Date of purchase ________________________________________________ Dealer s address ________________________________________________ Phone number ________________ Alert Symb...

Page 3: ... 5 hours before operation Leave the power mains ON unless you will not be using this appliance for an extended period Never touch the unit with wet hands Never use or store gasoline or other flammable vapor or liquid near the air conditioner it is very dangerous This air conditioner has no ventilator for intaking fresh air from outdoors You must open doors or windows frequently when you use gas or...

Page 4: ...ppliance by a person responsible for their safety Children should be supervised to ensure that do not play with the appliance Do not cool or heat the room too much if babies or invalids are present Do not sit or step on the unit You may fall down accidentally Do not stick any object into the FAN CASE You may be injured and the unit may be damaged The compressor may occasionally stop during thunder...

Page 5: ...ing mode to 30 C DBT Outdoor temperature range Cooling mode 15 C 43 C DBT Heating mode 20 C 15 C WBT DBT Dry bulb temperature WBT Wet bulb temperature Refer to the Instruction Manual attached to the optional Wireless Remote Control Unit Refer to the Instruction Manual attached to the optional Timer Remote Control Unit NOTE Wireless type available for all indoor units NOTE Wired type available for ...

Page 6: ... in some cases and the STANDBY indicator appears on the display until defrosting is completed Heating operation then restarts after several minutes This interval will vary slightly depending upon the outdoor temperature and the way in which frost forms standby on the display For several minutes after the start of heating operation the indoor fan will not start running or it will run at very low sp...

Page 7: ... brush or wipe them with a clean soft cloth If these parts are stained use a clean cloth moistened with water When cleaning the air outlet side be careful not to force the vanes out of place 1 Never use solvents or harsh chemicals when cleaning the indoor unit Do not wipe plastic parts using very hot water 2 Some metal edges and the fins are sharp and may cause injury if handled improperly be espe...

Page 8: ... improve the airflow 2 Heat source or many people in room 2 Eliminate heat source if possible 3 Doors and or windows are open 3 Shut them to keep the heat or cold out 4 Obstacle near air intake or air discharge port 4 Remove it to ensure good airflow 5 Thermostat is set too high for cooling or too low for heating 5 Set the temperature lower or higher 6 Defrosting system does not work 6 Consult you...

Page 9: ...batteries correctly you will help to save valuable resources and prevent any potential negative effects on human health and the environment which could otherwise arise from inappropriate waste handling For more information about collection and recycling of old products and batteries please contact your local municipality your waste disposal service or the point of sale where you purchased the item...

Page 10: ...8 Hi 47 Me 46 Lo Sound Power Level dB A 71 Unit Dimensions H W D mm 1526 940 340 467 1428 1230 Net Weight kg 118 110 Model Name Outdoor Unit Indoor Unit U 250PE1E8 S 250PE1E8 Power Source 380 400 415 V 3 phase 50 60 Hz 220 230 240 V single phase 50 60 Hz Cooling Capacity kW 25 0 6 0 28 0 BTU h 85 300 20 500 95 500 Heating Capacity kW 28 0 6 0 31 5 BTU h 95 500 20 500 107 500 Sound Pressure Level d...

Page 11: ...Authorized representative in EU Panasonic Testing Centre Panasonic Marketing Europe GmbH Winsbergring 15 22525 Hamburg Germany Printed in Japan ...

Reviews: