background image

– VRF System Air Conditioner –

■ 

R410A Models

Model No.

Indoor Units

Type Indoor Units 

Type

Rated Capacity

15

22

28

36

45

56

Y2 4-Way Cassette 

60×60

S-15MY2E5A 

(CZ-KPY3A)*

(CZ-KPY3B)*

S-22MY2E5A 

(CZ-KPY3A)*

(CZ-KPY3B)*

S-28MY2E5A 

(CZ-KPY3A)*

(CZ-KPY3B)*

S-36MY2E5A 

(CZ-KPY3A)*

(CZ-KPY3B)*

S-45MY2E5A 

(CZ-KPY3A)*

(CZ-KPY3B)*

S-56MY2E5A 

(CZ-KPY3A)*

(CZ-KPY3B)*

*Panel (optional parts)

ENGLISH

Read through the Installation Instructions before you proceed with the installation. 

In particular, you will need to read under the “IMPORTANT!” section at the top of the page.

FRANÇAIS

Lisez les instructions d’installation avant de commencer l’installation.

En particulier, vous devez lire la section “IMPORTANT!” en haut de la plage.

ESPAÑOL

Lea las Instrucciones de instalación antes de proceder con la instalación del equipo.

En concreto, deberá leer detenidamente la sección “¡IMPORTANTE!” situada al principio de la página.

DEUTSCH

Lesen Sie die Einbauanleitung, bevor Sie mit der Installation beginnen.

Insbesondere die Hinweise im Abschnitt “WICHTIG!” oben auf der Seite müssen unbedingt gelesen werden.

ITALIANO

Leggere le Istruzioni di installazione prima di procedere con l’installazione.

Prestare particolare attenzione alla sezione “IMPORTANTE!” all’inizio della pagina.

NEDERLANDS

Lees de installatie-instructies zorgvuldig door voor u begint met de installatie.

U moet vooral het gedeelte waar “BELANGRIJK!” boven staat heel goed lezen.

PORTUGUÊS

Leia cuidadosamente as instruções de instalação antes de prosseguir com a instalação.

Em particular, é necessário ler as informações na secção “IMPORTANTE!” na parte superior da página.

ΕΛΛΗΝΙΚΆ

Διαβάστε τις Οδηγίες εγκατάστασης πριν συνεχίσετε με την εγκατάσταση.

Συγκεκριμένα, θα χρειαστεί να διαβάσετε την ενότητα «ΣΗΜΑΝΤΙΚΟ!» στο πάνω μέρος της σελίδας.

БЪЛГАРСКИ

Прочетете инструкциите за инсталиране преди да продължите с инсталирането.

В частност, ще трябва да прочетете раздела „ВАЖНО!“ в горната част на страницата.

РУССКИЙ

Перед выполнением установки прочтите инструкцию по установке.

В частности, вам следует прочесть раздел «ВАЖНО!» вверху страницы.

УКРАЇНСЬКА

Перш ніж продовжити встановлення, прочитайте вказівки зі встановлення.

Зокрема, обов’язково прочитайте розділ «ВАЖЛИВО!» вгорі сторінки.

B.INDONESIA

Bacalah seluruh Petunjuk Pemasangan sebelum Anda melakukan pemasangan. 

Secara khusus, Anda perlu membaca bagian “PENTING!” di bagian atas halaman.

for Refrigerant R410A

INSTALLATION INSTRUCTIONS

F616379

Pana_indoor_F616379_L.indb   1

2014-9-17   11:18:50

AMP Air Conditioning

www.ampair.co.uk | [email protected]

Summary of Contents for S-15MY2E5A CZ-KPY3A

Page 1: ...al principio de la p gina DEUTSCH Lesen Sie die Einbauanleitung bevor Sie mit der Installation beginnen Insbesondere die Hinweise im Abschnitt WICHTIG oben auf der Seite m ssen unbedingt gelesen werd...

Page 2: ...tructions when wiring Improper connections and inadequate grounding can cause accidental injury or death Connect all wiring tightly Loose wiring may cause overheating at connection points and a possib...

Page 3: ...ts Clean up the site after you finish remembering to check that no metal scraps or bits of wiring have been left inside the unit being serviced WARNING WARNING This product must not be modified or dis...

Page 4: ...unt charged in the field and 1 2 the total refrigerant charge on the refrigerant charge label supplied with the product The filled out label must be adhered in the proximity of the product charging po...

Page 5: ...shielded wires Wiring samples 5 How to Process Tubing 13 5 1 Connecting the Refrigerant Tubing 5 2 Connecting Tubing Between Indoor and Outdoor Units 5 3 Insulating the Refrigerant Tubing 5 4 Taping t...

Page 6: ...y for hanging bolts and nuts 1 3 Type of Copper Tube and Insulation Material If you wish to purchase these materials separately from a local source you will need 1 Deoxidized annealed copper tube for...

Page 7: ...ay cause condensation on the air discharge ports causing them to spray or drip water locations where the remote controller will be splashed with water or affected by dampness or humidity installing th...

Page 8: ...m local supply Drain piping must have down slope 1 50 to 1 100 be sure not to provide up and down slope to prevent reversal flow Be sure to check no air trap on drain hose and to ensure smooth water f...

Page 9: ...aken when wiring as follows The remote control wiring and the inter unit control wiring should be wired apart from the inter unit power wiring Use shielded wires for inter unit control wiring between...

Page 10: ...R1 R2 R1 R2 R1 2 1 2 1 U2 U1 L N U2 U1 L N U2 U1 L N 2 1 2 1 2 1 D E C B L N L N L N L N 2 1 B B B C D D C 2 1 A L1 L2 L3 N A L1 L2 L3 N F C L1 L2 L3 N L1 L2 L3 N U1 U2 2 1 Power supply 220 230 240V...

Page 11: ...unit Indoor unit Indoor unit Outdoor unit Branch point More than 2m required Fig 4 5 5 Use shielded wires for inter unit control wiring c and ground the shield on both sides otherwise misoperation fro...

Page 12: ...eplace and tighten the removed terminal screw using a screwdriver Fig 4 8 Examples of shielded wires 1 Remove cable coat not to scratch braided shield Fig 4 9 2 Unbraid the braided shield carefully an...

Page 13: ...nnections This is effective for reducing gas leaks Fig 5 4 Apply refrigerant lubricant Fig 5 4 3 For proper connection align the union tube and flare tube straight with each other then screw on the fl...

Page 14: ...pe around the flare nuts at the gas tube connections Then cover up the tubing connections with the flare insulator and fill the gap at the union with the supplied black insulation tape Finally fasten...

Page 15: ...The direction of the installation is free 2 Fitting the decorative panel Temporarily secure the fixing screws 3 pcs before fitting the decorative panel For temporarily securing the front grille 5 4 Ta...

Page 16: ...Front grille fixing screws 4 pcs Tighten this screw first after hanging the grille frame Securing the tentative fixing screw Fig 7 4 CAUTION Check before hand the height from the ceiling to the unit...

Page 17: ...slide the knob to the OPEN side 2 Slowly pull down the intake grille 3 Remove the air filter from the tabs and pull it downwards Remove Air Filter Installation 1 2 3 Insert the air filter to the tabs...

Page 18: ...hanges while operating Wind direction setting cannot be made Wind direction cannot be changed When air discharge temperature is low or during defrost operation horizontal wind flow is made automatical...

Page 19: ...u checked the points as described above first stop the operation and turn off the power switch Then contact your dealer and report the serial number and symptom Never repair your air conditioner by yo...

Page 20: ...20 NOTE Pana_indoor_F616379_L indb 20 2014 9 17 11 19 18 AMP Air Conditioning www ampair co uk sales ampair co uk...

Reviews: