10.2.2 Reading the Latest Image of PV500
The latest image of PV500 can be read out on the camera window of PVWIN by a command from PVWIN.
Regardless of the displayed menu (SETUP/RUN) and running status of PV500, reading the image can be
executed.
When the image receiving software Image Receiver is running on the PC where PVWIN is running, you cannot
read out the latest image.
1.
Execute an inspection in RUN menu of PV500.
The inspected image can be read with PVWIN. When no inspection is executed, PVWIN cannot read
because there is no image to read.
2.
Execute image reading from PV500 with PVWIN.
The latest image of PV500 is read out.
When "Detect Trigger (Common)" is used as Camera Trigger, the device reads the image of when detect
trigger is executed. When no detect trigger is executed, image cannot be read because there is no image to
read. (Although a memory image is displayed even when no detect trigger is executed, the memory image
cannot be read.)
When communication error occurs
When a communication error occurs, the message is displayed on the screen of PVWIN or PVWIN and PV500.
Execute again after solving the problem described on the message.
10.2.3 Uploading Images in Storage Space in PV500
This is the function that efficiently saves the images stored in the storage space in PV500 (Ver.1.40 or later)
into a PC by a command from PVWIN (Ver.1.10 or later). To use this function, “PC Communi.” menu of PV500
needs to be selected in SETUP menu.
1.
Go to SETUP menu and select “TOOL” > “PC Communi.”
from the menu bar.
The PV500 becomes to be able to communicate with PC and
the current communication status is displayed under the menu.
2.
Execute communication from PVWIN.
Specifying the destination of images with PVWIN starts communication. The display of PV500 changes to
“Transmitting…” Pressing the CANCEL key during the communication stops the transmitting and the
display changes to “Terminating...” and eventually to “Standby”.
When communication error occurs
When the devices cannot communicate, the display shows “Communication Error”. (When the next
transmission is executed, the display changes to “Transmitting...”)
When a communication error occurs, the notice is displayed on the screen of PVWIN or PVWIN and
PV500. Execute again after solving the problem described on the message.
3.
After transmission is completed, press the CANCEL key to cancel the communication mode.
About File Name
Images are saved in the specified folder as the following name.
“Cn_NNN.bmp”
•
Cn_: Camera No. C0_ to C3_
•
NNN: Image No. 000 -
Summary of Contents for PV-500
Page 1: ......
Page 10: ......
Page 11: ...9 Names and Descriptions Chapter 1 INDEX Chapter 1 Names and Descriptions ...
Page 21: ...19 Installation and Wiring Chapter 2 INDEX Chapter 2 Installation and Wiring ...
Page 37: ...35 Basic Operation Chapter 3 INDEX Chapter 3 Basic Operation ...
Page 55: ...53 Setting Inspection Conditions Chapter 4 INDEX Chapter 4 Setting Inspection Conditions ...
Page 345: ...343 Chapter 7 Changing Configuration INDEX Chapter 7 Changing Configuration TOOL ...
Page 375: ...373 Operation and Data Output through I O Terminals Chapter 8 INDEX ...
Page 390: ......
Page 391: ...389 Control with Communication Port Chapter 9 INDEX Chapter 9 Control with Communication Port ...
Page 430: ......
Page 431: ...429 PVWIN Chapter 10 INDEX Chapter 10 PVWIN ...
Page 493: ......
Page 494: ......