Setting PLC Communication
Make setting to output data in PLC Communication.
When using RS-232C Interface
For the information of how to set Baud Rate and transmission format, refer to page 339.
1.
Select "ENVIRONMENT" > “Input/Output”
> “General Output” from the menu bar.
2.
Select “Serial (COM.0)” for “Destination”.
3
. Set “Protocol” to “PLC Communication”.
4
. Set “Scan Count”, “Total Judgement”,
“Judgement”, and “Numerical
Calculation” to “Output” as necessary.
5
. Select a destination in “PLC Type”.
6.
Press “Set” button of “PLC
Communication Setting”.
The PLC communication setting menu is
displayed.
7
. Only when selecting "Panasonic: FP" for PLC Type, set "Specify Station No.".
Station Home
(Default):
A command which specifies no station number is issued.
Example) %EE#WDD0001
⋅
⋅
⋅
⋅
⋅
Specify Station No.
(Station No.:1 – 99):
A command for a PLC with the specified station number is issued. Specify the same number of the station
number that is set for the PLC to communicate in "Station No.".
Example) When Station No. is 99
%99#WDD0001
⋅
⋅
⋅
⋅
⋅
8
. In “Start Register”, specify the first register number of the PLC that PV500 outputs data into.
0 to 99999 are available.
Not all addresses 0 to 99999 can be used in destination PLC. As the address allowed to be written by the
external device (PV500) varies depending on PLC, please make sure the address with the instruction
manual of PLC.
9
. Select 16-bit or 32-bit to output Scan count and Numerical calculation data in “Bit Width”.
When output data exceeds the value which can be output in the selected Bit Width, "0" is output.
Summary of Contents for PV-500
Page 1: ......
Page 10: ......
Page 11: ...9 Names and Descriptions Chapter 1 INDEX Chapter 1 Names and Descriptions ...
Page 21: ...19 Installation and Wiring Chapter 2 INDEX Chapter 2 Installation and Wiring ...
Page 37: ...35 Basic Operation Chapter 3 INDEX Chapter 3 Basic Operation ...
Page 55: ...53 Setting Inspection Conditions Chapter 4 INDEX Chapter 4 Setting Inspection Conditions ...
Page 345: ...343 Chapter 7 Changing Configuration INDEX Chapter 7 Changing Configuration TOOL ...
Page 375: ...373 Operation and Data Output through I O Terminals Chapter 8 INDEX ...
Page 390: ......
Page 391: ...389 Control with Communication Port Chapter 9 INDEX Chapter 9 Control with Communication Port ...
Page 430: ......
Page 431: ...429 PVWIN Chapter 10 INDEX Chapter 10 PVWIN ...
Page 493: ......
Page 494: ......