412
C
o
nt
rol
w
it
h C
om
m
uni
c
a
tion P
or
t
C
h
ap
te
r 9
Details of Read out/write Command Parameter
When writing maximum and minimum values in sets using %PWP command, specify maximum values in
Data 1 and minimum values in Data 2. When reading two data in sets using %PRP command, the data is
output in the same order.
System values
Parameter
Read
Write
Minimum
value
Maximum
value
Details
Inspection time
SYS_TIME1
Yes
0.00
9999.00
When exceeding the
upper limit, 10000.00 is
output.
Inspection Cycle
SYS_TIME2
Yes
0.00
9999.00
Total Judgement
SYS_RESULT
Yes
0
1
0:NG 1: OK
Scan Count
SYS_COUNT
Yes
0
2147483647
Window Status
SYS_EDIT
Yes
0
1
0: RUN menu,
1: SETUP menu
Operation Status
SYS_RUN
Yes
0
1
0: RUN, 1: STOP
Current Type No.
SYS_TYPE
Yes
0
255
Date
SYS_DATE
Yes
Yes
YYYY/MM/DD
(4-digit of year/ 2-digit
of Month/ 2-digit of
Day)
Time
SYS_TIME
Yes
Yes
HH:MM:SS
(2-digit of Hour:
2-dgit of Minute:
2-digit of Second)
System Register 0
to System Register
7
SYS:REG0
Yes
Yes
-9999999.999 9999999.999
Up to 3-digit is
available after decimal
point.
Slice Level
The symbol of “?” shown in parameters is a slice level group (A - Z)
Parameter
Read
Write
Minimum
value
Maximum
value
Details
Maximum value
BLV:H?
Yes
Yes
0
255
Minimum value
BLV:L?
Yes
Yes
0
255
Maximum and
Minimum values
BLV:PAIR?
Yes
Yes
0
255
Data 1 = Min.
Data 2 = Max.
Checker
The symbol of “nnn” shown in parameters is a checker number (000 - 999).
Line
Parameter
Read
Write
Minimum
value
Maximum
value
Details
Max. No. of Pixels.
LICnnn:DMAX
Yes
Yes
0
125938
Min. No. of Pixels.
LICnnn:DMIN
Yes
Yes
0
125938
Max. and Min. No. of
Pixels.
LICnnn:DPAIR
Yes
Yes
0
125938
Data 1 = Min.
Data 2 = Max.
Max. No. of Objects
LICnnn:LMAX
Yes
Yes
0
41979
Min. No. of Objects
LICnnn:LMIN
Yes
Yes
0
41979
Max. and Min. No. of
Objects
LICnnn:LPAIR
Yes
Yes
0
41979
Data 1 = Min.
Data 2 = Max.
Binary Window
Parameter
Read
Write
Minimum
value
Maximum
value
Details
OK Judge. Max.
BWCnnn:MAX
Yes
Yes
0
1920000
OK Judge. Min.
BWCnnn:MIN
Yes
Yes
0
1920000
OK Judge. Max. and
Min.
BWCnnn:LPAIR
Yes
Yes
0
1920000
Data 1 = Min.
Data 2 = Max.
Summary of Contents for PV-500
Page 1: ......
Page 10: ......
Page 11: ...9 Names and Descriptions Chapter 1 INDEX Chapter 1 Names and Descriptions ...
Page 21: ...19 Installation and Wiring Chapter 2 INDEX Chapter 2 Installation and Wiring ...
Page 37: ...35 Basic Operation Chapter 3 INDEX Chapter 3 Basic Operation ...
Page 55: ...53 Setting Inspection Conditions Chapter 4 INDEX Chapter 4 Setting Inspection Conditions ...
Page 345: ...343 Chapter 7 Changing Configuration INDEX Chapter 7 Changing Configuration TOOL ...
Page 375: ...373 Operation and Data Output through I O Terminals Chapter 8 INDEX ...
Page 390: ......
Page 391: ...389 Control with Communication Port Chapter 9 INDEX Chapter 9 Control with Communication Port ...
Page 430: ......
Page 431: ...429 PVWIN Chapter 10 INDEX Chapter 10 PVWIN ...
Page 493: ......
Page 494: ......