Selecting Output Condition
Other than outputting by an inspection, images can be output when the specified conditions are fulfilled.
1.
Select a condition to output images in “Output Condition”.
[All Images](default):
Outputs images at every inspection.
[NG Judgement]:
Outputs images when the judgement selected in “Image Output” is NG. (Refer
to page 248.)
If any condition is not specified, no image is output.
Outputs all images of the cameras which set to "Output" according to the result
of one judgement expression.
[At Interval]:
Outputs images per the specified number of inspections.
[Command Reception]:
Outputs images when receiving the certain signal* from external device.
* The signal of "Output Latest Image" assigned to one of ASSIGN 0-5.
[Judge. Per Cam.]:
(Available from
Ver.2.30)
Outputs images when the judegment selected in “Image Output” in
“Judgment” for each camera is NG. (Refer to page 248.)
Images are output each time when selecting "No Condition" for "Image
Output".
If any condition is not specified, no image is output.
Judgement formula which is used as output condition can be specified per
camera. As only the images of the camera the result of which is NG can be
output, the transmission time of images and the image capacity can be
reduced.
2.
Set an interval in “Interval”.
(This is the item to set when you select "At Interval" in Step 1.)
The range of available value is 2 to 10000.
Specifying “10” outputs an image at the first inspection, and then outputs every ten inspections as 11th time,
21st time, 31st time…
Selecting Output Timing
Set the timing to output images.
There are two settings; to output images every time one inspection is executed, to output images while PV500
is able to output them until the start of the next inspection.
Refer to page 335 for details.
Selecting Additional Information for a File Name
A file name of image consists of the following information.
Header:
Up to eight characters can be specified.
Additional information 0-3:
Four types of information can be added.
Type No.:
Type No. (000 - 255) when the image is captured.
Date:
The date (yymmdd) of built-in calendar of PV500 when the image is captured.
Time:
The time (hhmmss) of built-in calendar of PV500 when the image is captured.
Total Judgement
(Result):
Total judgement of the image (OK/NG)
* Total judgement is other than OK/NG, such as NJ = Unset
Judge. Per Cam.
(Result):
Judgement of the image per camera (CJNJ /CJ NG / CJAL)
*CJNJ = When "Output Condition" is other than "Judge. Per Cam.”
*CJAL = When "Image Output" set in Judgement is "No Condition"
Camera No.:
C0 - C3 (2 digits) Number of the camera which captured the image.
Scan Count:
Scan count: 7 digits
Summary of Contents for PV-500
Page 1: ......
Page 10: ......
Page 11: ...9 Names and Descriptions Chapter 1 INDEX Chapter 1 Names and Descriptions ...
Page 21: ...19 Installation and Wiring Chapter 2 INDEX Chapter 2 Installation and Wiring ...
Page 37: ...35 Basic Operation Chapter 3 INDEX Chapter 3 Basic Operation ...
Page 55: ...53 Setting Inspection Conditions Chapter 4 INDEX Chapter 4 Setting Inspection Conditions ...
Page 345: ...343 Chapter 7 Changing Configuration INDEX Chapter 7 Changing Configuration TOOL ...
Page 375: ...373 Operation and Data Output through I O Terminals Chapter 8 INDEX ...
Page 390: ......
Page 391: ...389 Control with Communication Port Chapter 9 INDEX Chapter 9 Control with Communication Port ...
Page 430: ......
Page 431: ...429 PVWIN Chapter 10 INDEX Chapter 10 PVWIN ...
Page 493: ......
Page 494: ......