257
Se
tt
ing I
n
s
p
e
c
tio
n C
on
d
it
ions
C
h
ap
te
r 4
INDE
X
Copying and Deleting Figure
Figures can be deleted or copied from the pop-up menu to be displayed by pressing the FUNC key.
1.
Highlight the figure number you want to delete or copy and
press the FUNC key.
2.
Select "Delete" or "Copy".
When selecting "Delete", the dialog message appears. Select
“YES".
3.
When selecting "Copy", move the cursor onto the figure
number to paste, press the FUNC key, and select “Paste”.
The copied figure is pasted.
If a figure already exists in the destination, the message of overwrite
confirmation appears. Select “Yes” to overwrite it.
4.13.3 Setting the Drawing Position and Size of a Drawing
Line (Straight Line)
Specify the X and Y coordinates of the start and end points to display a line. The start and end points can be
specified with the cursor, values and the coordinates detected by each checker. For details of selectable items,
see page 266.
Specifying Start Point and End Point
1.
Select the table to set the start point XY and end point XY on the
setting window of Line, and move the cursor onto "Start X" and
press the ENTER key.
A list of available items is displayed. (The checkers displayed in gray
indicates that they are not unset.)
2.
Select the item to input in Start X from the list of the selectable
items.
When selecting "Cursor", move the cross mark displayed on the screen
window and press the ENTER key.
About the items that X and Y-coordinates are input together
When selecting items other than Numerical Calculation, System
Register and Constant, X and Y-coordinates are input together.
For example, when selecting "GEC: Gray Edge" for setting Start X, the
XY-coordinate of the detected edge is input for Start X and Start Y.
If Start Y has been already input, it is overwritten.
If you want to set the item that the X and Y-coordinates are input
together to X-(or Y-)coordinate and the item that a single coordinate is
input such as Numerical Calculation, System Register or Constant to
Y-(or X-)coordinate, specify the item that the coordinates are input
together first and then specify the item that a single coordinate is input.
3.
In the same way, set Start Y, End X and End Y.
Summary of Contents for PV-500
Page 1: ......
Page 10: ......
Page 11: ...9 Names and Descriptions Chapter 1 INDEX Chapter 1 Names and Descriptions ...
Page 21: ...19 Installation and Wiring Chapter 2 INDEX Chapter 2 Installation and Wiring ...
Page 37: ...35 Basic Operation Chapter 3 INDEX Chapter 3 Basic Operation ...
Page 55: ...53 Setting Inspection Conditions Chapter 4 INDEX Chapter 4 Setting Inspection Conditions ...
Page 345: ...343 Chapter 7 Changing Configuration INDEX Chapter 7 Changing Configuration TOOL ...
Page 375: ...373 Operation and Data Output through I O Terminals Chapter 8 INDEX ...
Page 390: ......
Page 391: ...389 Control with Communication Port Chapter 9 INDEX Chapter 9 Control with Communication Port ...
Page 430: ......
Page 431: ...429 PVWIN Chapter 10 INDEX Chapter 10 PVWIN ...
Page 493: ......
Page 494: ......