Setting Judgement Limits
1.
Select the table of maximum/minimum values in "Judgement Limits" setting window.
2.
Specify the maximum and minimum measurement values of radius (diameter/width).
As the maximum and minimum measurement values are displayed at the bottom of the screen, make the
setting checking it.
In addition, red lines indicating the maximum and minimum values are displayed in the graph. Confirm
them and set.
3.
Specify the maximum and minimum values of standard deviation and circularity.
As the current value of each condition is displayed at the bottom of the screen, make the setting checking
it.
4.
Specify the maximum value for "Unused Edge Count".
The current value of the unused edge count (test result) is displayed on the left of the screen. Confirm it
and set.
The default for the maximum number of settable cells is 3597.
Summary of Contents for PV-500
Page 1: ......
Page 10: ......
Page 11: ...9 Names and Descriptions Chapter 1 INDEX Chapter 1 Names and Descriptions ...
Page 21: ...19 Installation and Wiring Chapter 2 INDEX Chapter 2 Installation and Wiring ...
Page 37: ...35 Basic Operation Chapter 3 INDEX Chapter 3 Basic Operation ...
Page 55: ...53 Setting Inspection Conditions Chapter 4 INDEX Chapter 4 Setting Inspection Conditions ...
Page 345: ...343 Chapter 7 Changing Configuration INDEX Chapter 7 Changing Configuration TOOL ...
Page 375: ...373 Operation and Data Output through I O Terminals Chapter 8 INDEX ...
Page 390: ......
Page 391: ...389 Control with Communication Port Chapter 9 INDEX Chapter 9 Control with Communication Port ...
Page 430: ......
Page 431: ...429 PVWIN Chapter 10 INDEX Chapter 10 PVWIN ...
Page 493: ......
Page 494: ......