Circuit Protections
The projector will be automatically turned off when the internal temperature of the projector is abnormally high, or the
cooling fans stop spinning, or the power supplies in the projector are failed.
Warning temperature and power failure protection
The projector is shut down and the WARNING indicator lights red.
When the projector detects an abnormal condition, it is automatically shut down to protect the inside of the projector
and the WARNING indicator lights red. In this case, unplug the AC power cord and reconnect it, and then turn the
projector on once again to verify operation.
WARNING
DO NOT LEAVE THE PROJECTOR WITH THE AC POWER CORD CONNECTED UNDER AN
ABNORMAL CONDITION. IT MAY RESULT IN FIRE OR ELECTRIC SHOCK.
4
Note:
- If the WARNING indicator lights red, it may defect the cooling fans or power supply circuits. Check fans operation
and power supply lines referring to the chapter “Power supply & protection circuit” and "Fan control circuit" in the
Chassis Block Diagram section.
When the temperature inside the projector reaches a certain level, the projector will be automatically shut down to
protect the inside of the projector and the WARNING and ON(G)/STANDBY(R) indicators start blinking. When the
projector has cooled down enough (to its normal operating temperature), the ON(G)/STANDBY(R) indicator stops
blinking and lights red, The projector can be turned on again by pressing the
button.
4
Note:
The WARNING indicator continues to blink even after the temperature inside the projector returns to normal. When
the projector is turned on again, the WARNING indicator stops blinking.
Check items
- Remove dust around the air filter.
- Ventilation slots of the projector are blocked. In such an event, reposition the projector so that ventilation slots are
not obstructed.
- Check if projector is used at higher temperature.
The projector is shut down and the WARNING indicator is blinking red.
LED indicator
WARNING
indicator
ON(G) / STANDBY(R)
indicator
Summary of Contents for PT-VW430E
Page 83: ... 83 IC Block Diagrams CXA3828GL E S H IC561 TLV320AIC3105 Audio control IC5001 ...
Page 84: ... 84 IC Block Diagrams PW190 Scaler IC301 TB6608FNG IRIS Driver IC601 ...
Page 85: ... 85 IC Block Diagrams SSC9512S Power Switching IC604 PIC32MX695F512H Netwrok IC8801 ...
Page 86: ... 86 IC Block Diagrams TPS54286 DC DC converter IC7811 STR A6079 Power switching IC603 ...
Page 116: ......