Chapter 7
Appendix — Attaching the Smoke Cut Filter Unit (optional)
278 - ENGLISH
Attaching the Smoke Cut Filter Unit (optional)
The optional Smoke Cut Filter (Model No.: ET-SFR330) is attached when using the projector in an environment
generating smoke such as an event. Attach the Smoke Cut Filter instead of the standard air filter unit attached to
the projector.
When purchasing the optional Smoke Cut Filter (Model No.: ET-SFR330), consult your dealer.
Attention
f
Make sure to turn off the power before removing the standard air filter unit attached to the projector and attaching the optional Smoke Cut
Filter. (
f
Make sure that the projector is stable, and perform the maintenance in a safe place even if the filter falls accidentally.
Note
f
The Smoke Cut Filter cannot be used at an altitude of 1 400 m (4 593') or higher and in an operating environment where the temperature
exceeds 40 °C (104 °F).
f
Set [OPERATING MODE] to anything other than [LONG LIFE1], [LONG LIFE2], or [LONG LIFE3] when using the optional Smoke Cut Filter
(Model No.: ET-SFR330).
f
The Smoke Cut Filter cannot be maintained, recycled, or reused. Make sure to replace it with an unused one.
Removing the air filter unit
First, remove the standard air filter unit attached to the projector.
Grip on the air filter unit (b)
Grip on the air filter unit (a)
Fig. 3
Fig. 2
Fig. 1
Air filter cover
Air filter unit
Tabs on the projector body (d)
Tabs on the projector body (c)
Air filter cover fixing screw
Air filter unit compartment and the
projector’s air intake port
1) Turn off the power of the projector.
f
When switching off the projector, make sure to follow the procedures in “Switching off the projector”
2) Open the air filter cover. (Fig. 1)
f
Use a Phillips screwdriver to turn the air filter cover fixing screw counterclockwise until it turns freely, and
open the air filter cover for approximately 90°.
f
Loosen the air filter cover fixing screw while holding the air filter cover with your hand.
3) Pull out the air filter unit.
i) Pull out the air filter unit from the tabs on the projector body (c) while slightly pressing the grip on the air filter
unit (a) inward as described with the arrow.
(Fig. 2)
ii) Pull out the air filter unit.
(Fig. 3)
f
When pulling out, confirm that the air filter unit comes off from the tabs on the projector body (d).
f
After pulling out the air filter unit, remove large foreign objects and dust from the air filter unit compartment
and the air intake port of the projector body if there are any.
f
When the air filter unit is removed, proceed to “Attaching the Smoke Cut Filter” (
Attention
f
Take care not to touch the radiator fin, etc., when removing dirt or dust.