E
NGLISH
-59
Care
and
maintenance
Cleaning and replacing the air filter
If the air filter becomes clogged with dust, the internal temperature of the
projector will rise, the TEMP indicator will illuminate and the projector’s
power will turn off (the TEMP indicator will flash after the power is turned off).
The air filter should be cleaned every 100 hours of use.
%
Replace the air filter, and then
install the air filter cover.
Cleaning
Use a vacuum cleaner to clean off
any accumulated dust.
Replacement procedure
#
Turn off the power and
disconnect the mains lead.
Be sure to disconnect the mains
lead by following the procedure
given on page 28.
$
Gently turn the projector
upside down, and then remove
the air filter cover.
NOTE:
B
If the dust cannot be cleaned
by a vacuum cleaner, remove
the air filter and soak it in
water, and then wash out the
dust by hand. Be sure to install
the air filter after it has dried.
B
Do not use detergent when
washing the air filter.
B
If the dust cannot be removed
by cleaning, it is time to
replace the air filter. Please
consult your dealer.
Furthermore, if the lamp unit is
being replaced, replace the air
filter at this time also.
NOTE:
B
Be sure to install the air filter
before using the projector. If
the projector is used without
the air filter installed, dust and
other foreign particles will be
drawn into the projector, and
malfunctions will result.
Air filter cover
Air filter
Air filter cover
Summary of Contents for PT-LB55
Page 2: ......
Page 25: ...ENGLISH 25 Getting started ...