4.4 Make protective settings
5
Start trial operation
After the servo function has been activated and all parameters have been set, you can start
the trial run.
1. On the “TrialRun” tab, select “Go Trial Run”.
The “Test Operation” dialog opens.
2. Make the following settings:
a. “Distance”: The movement amount in pulses must be within the movement amount
set by “MAX (pulse)” and “MIN (pulse)”.
b. “Waiting time”: Waiting between forward and reverse movements in ms for repetitive
(“JOG Cont”) or continuous mode (“STEP Cont”).
c. “Speed”: Maximum speed in rev/min
d. “Acceleration/Deceleration”: Acceleration and deceleration time for trapezoidal
movement in ms
3. Select “ZERO” to move the motor to the 0 position.
4. Select “STEP Cont”.
This sets the continuous mode. This mode is the easiest way to implement a repetitive
operation pattern.
5. Select one of the “JOG” buttons for movement in positive or negative direction.
“Test Operation” dialog of the “TrialRun” tab
6. If want to change any of the settings in this dialog, select “PAUSE”.