5.3 FIRMWARE HANDLING
At the
testing
tab firmware can be downloaded (
Download image
) to the EVB and a number
of changes can be made to it (
Change BD-data
) like assigning a unique BT address (e.g.
0003199E8B
73
) and oscillator trim value. Make sure that the
Production mode
is enabled
before any of these buttons on this tab are used. To do this mark
On
and confirm with a click
on
Production mode
. The text field should inform you about of success of this procedure. Be
advised to do a hardware reset (push button on EVB) after all changes were made.
Please note:
The BD_Address and OSC_Trim value have to be read out by “Read BD Address” command
before downloading. They have to be programmed by “Change BD-data” command after
writing the new image.