file:///L|/Panasonic/Video/NV-MV/NV-MV20EG/NV-MV20EG_NV-...20EB_NV-MV20EBL_NV-MV15EG_NV-MV15EP/SVC/s0303040000.html
3.3.4 PG SHIFTER ADJUSTMENT
(AUTOMATIC)
PROCEDURES
FIP DISPLAY
Press the FF and EJECT Keys
simultaneously for 3 seconds.
Press the FF and EJECT Keys
simultaneously twice.
Press the EJECT key for 3 seconds.
Press the CH UP key once.
Insert the Alignment cassette tape. (PAL:VFJ8125H3F)
When the sequence of the automatical adjustment has been terminated, the following action has been made.
*SUCCEED: The cassette tape is ejected.
*ERROR : The "F2"is displayed on the FIP.
(Check the Servo/Syscon circuit and Cylinder unit.)
Release the Service mode by pressing the EJECT and FF keys simultaneously in 6 times until the FIP becomes normal indication.
Fig. E3