- 3 -
NC-TWS30
1.2. Dismantle Procedure for
Failure Diagnotics
Tapping screw
(M4 x 12)
Truss head screw
Bottom plate
Sleeve
Screw B
Waterproof
cover B
Body
Thermo pot may break down by static
electricity from clothes, human body,
workbenches, etc. when toutch or wonder to
toutch should to ground human body with
several MΩ.
SOMETHING REQUEST
Do not do maintennance and re-use if copper
pattern on PCB is broken.
1. Remove 2 Tapping screws and 1 Truss head
screw from Bottom plate.
2. Remove 1 screw and Sleeve from Body.
3. Remove white, orange Lead wire and Earth
wire from Peg frame.
4. Remove Body off.
5. Remove Water proof cover B.
1.3. Check points
Fig. 1
Insert the direction to Pin Base where Faston Terminal is inserted so
that the curl part may become direction of this figure. (2 positions)
# Tighten the screw securely and completely, allowing no
gap between the screw head and the counterpart.
# The additional-tightening torque shall be 70~120N • cm
(7.1~12.2kgf • cm).
Pan Head Tapping Screw
Deltite Screw
Faston Terminal shall be securely inserted to the end.
Earth Wire Assy
Wire Q
Funen Ban
Wire B
View B
Wire A
Funen Tube
Wire S
Wire L
Wire P
Wire J
Discharge gap
Discharge gap