10 Troubleshooting Guide
10.1. Service check
1. Press and hold Power switch button.
2. Press and hold both the "Wash" and "Rinse" buttons with one hand.
i.e. Press and hold those three buttons simultaneously.
3. Release your fingers from the buttons.
After three seconds it's turn into check process "A".
4. Press the "Wash" button within three seconds, you can be select your desire Check process on by one.
(Carry out Check process "A
B
C
D
I
F
G1
G2
G3
H
P
L
″
and" V".)
Number of
times "Wash"
button is
pressed
Check
process
Checking contents
LED display indication
Operation contents
0
A
• Lighting-up all
three LED.
• Completed
message buzzer
• Auto power off
888
Panel display : "Wash" "Rinse" "Spin" and LED
display"888" blinks simultaneously.
• The buzzer beeps 3 times, LED blinks "888"
simultaneously.
And system will be turns off automatically.
• If controller have malfunction, LED display indicate
"002".
1
B
• Wash operation
check
• Operation check of
Feed valve for
softener
6
Panel display : "Wash "blinks, LED display"6"
(6 minutes) and then count down by one minute unit.
• Performs Wash process for 6 minutes, even if there
is no water in the dram.
• Pressing "Rinse "button once, can be perform of
electric continuity check of Feed valve for softener.
• Pressing "Rinse "button 3 times, it will back to the
Wash operation.
• If controller have malfunction, LED display indicate
"H05".
2
C
• Spin operation
check
• Operation check of
Lid lock switch
7
Panel display : "Spin"blinks, LED display"7"(7 minutes)
and then count down by one minute unit.
• Locks the Lid, performs Spin operation for 7
minutes.
• Perform a electric continuity check of Lid lock
switch.
When Lid lock switch "OFF" : "Times" LED will be
illuminate
3
D
• "d0"performs Dry
operation and "d1"
perform thermistor
calibration.
• "d0"and "d1"can
be change over by
pressing "Rinse"
button
Press "Start/Pause"
button for operation
start.
d0 and d1
The data are displayed by a number in LED display
during pressing below buttons.
• [Spin] Displays temperature(Deg.C) for Exhaust air
sensor(Th1).
• [Dry] Displays temperature(Deg.C) for Inlet air
sensor(Th2 ).
• [Time] Displays temperature(Deg.C) for Hot air
sensor(Th3 ).
• When heater On condition, "Auto"sign lights up.
d0
• Performs Dry operation for 10 minutes and then
count down by one minute unit.
Locks the Lid, performs the stirring operation, and
turns on the Heater, circulation fan and cooling fan.
(Drain valve(valve unit) always open. )
d1
• Performs Dry operation for 4 minutes and then
count down by one minutes unit.
Locks the door, performs circulation fan and cooling
fan turns on.
During this operation, Sensors done calibration by
scheduled measurement of Exhaust air sensor(Th1)
and Inlet air sensor(Th2).
After the calibration job finished, Service Check will
switch from "D" to "F" automatically.
Summary of Contents for NA-D106X1
Page 2: ...2 NA D106X1 1 Safety Precautions ...
Page 4: ...4 NA D106X1 3 General Introduction 3 1 Location of Components and Accessories ...
Page 5: ...5 NA D106X1 4 Control panel ...
Page 7: ...7 NA D106X1 5 3 Active Foam system 5 4 ECONAVI ...
Page 8: ...8 NA D106X1 5 5 Eco Drying system ...
Page 9: ...9 NA D106X1 6 Installation Instructions ...
Page 10: ...10 NA D106X1 ...
Page 11: ...11 NA D106X1 ...
Page 12: ...12 NA D106X1 ...
Page 13: ...13 NA D106X1 7 Operating Instructions 7 1 Door Lock and Child Lock ...
Page 14: ...14 NA D106X1 7 2 Laundry Procedure ...
Page 15: ...15 NA D106X1 7 3 Selecting the Program ...
Page 16: ...16 NA D106X1 7 4 How to Put in Detergent and Sofetner ...
Page 17: ...17 NA D106X1 7 5 Everyday Washing ...
Page 18: ...18 NA D106X1 7 6 Washing Options ...
Page 19: ...19 NA D106X1 ...
Page 20: ...20 NA D106X1 7 7 Drying ...
Page 21: ...21 NA D106X1 7 8 Maintenance ...
Page 22: ...22 NA D106X1 ...
Page 23: ...23 NA D106X1 7 9 Changing the Settings ...
Page 24: ...24 NA D106X1 7 10 Program Details ...
Page 46: ...46 NA D106X1 9 Wiring Diagram OUTLINE Drawing 9 1 NA D106X1 Wiring Diagram ...
Page 47: ...47 NA D106X1 9 2 Measure Input and Output value of Controller Power side ...
Page 56: ...56 NA D106X1 11 External Diameter ...
Page 57: ...57 NA D106X1 ...
Page 58: ...58 NA D106X1 12 Exploded View and Replacement Parts List 12 1 Parts Exploded View Part A ...
Page 60: ...60 NA D106X1 12 3 Parts Exploded View Part B ...
Page 62: ...62 NA D106X1 12 5 Parts Exploded View Part C ...
Page 64: ...64 NA D106X1 12 7 Parts Exploded View Part D ...
Page 66: ...66 NA D106X1 12 9 Parts Exploded View Part E ...