Auto Tuning Functions
5-44
5.2.9 Feed forward function
When position control or full closed control is used, positional deviation can be further reduced when
compared with deviation where control is made only by feedback, and response is also improved, by
calculating the velocity control command necessary for operation based on the internal positional command,
and by adding velocity feed forward to the velocity command calculated by comparison with position
feedback. In EtherCAT communication, speed feedforward can be set up at 60B1h/68B1h (Velociy offset)
apart from this.
The response time of the velocity control system is also improved by calculating torque command necessary
for operation based on the velocity control command and by adding torque feed forward calculated by
comparison with velocity feedback to the torque command. In EtherCAT communication, torque feedforward
can be set up by 60B2h/68B2h (Torque offset) apart from this.
The feed forward given through EtherCAT communication is added to the feed forward value (internally
calculated according to the parameter setting).
Relevant parameters
For MINAS A6 Multi series, the velocity feed forward and torque feed forward can be used.
Relevant parameters
Class No. Attribute
Title
Range
Unit
Function
1
10
B
Velocity feed
forward gain
0 to 4000 0.1%
Multiply the velocity control command calculated according to
the internal positional command by the ratio of this parameter
and add the result to the velocity command resulting from the
positional control process.
1
11
B
Velocity feed
forward filter
0 to 6400 0.01 ms Set the time constant of 1st delay filter which affects the input of
velocity feed forward.
It becomes invalid in two-degree-of-freedom control mode.
1
12
B
Torque feed
forward gain
0 to 2000 0.1%
Multiply the torque command calculated according to the
velocity control command by the ratio of this parameter and add
the result to the torque command resulting from the velocity
control process.
1
13
B
Torque feed
forward filter
0 to 6400 0.01 ms Set up the time constant of 1st delay filter which affects the
input of torque feed forward.
Summary of Contents for MINAS A6 Series
Page 10: ...Table of contents x Blank page...
Page 11: ...1 Introduction...
Page 26: ...Introduction 1 16 Blank page...
Page 27: ...2 Interface Specifications...
Page 46: ...Interface Specifications 2 20 Blank page...
Page 47: ...3 Front Panel Specifications...
Page 57: ...4 Basic Functions...
Page 85: ...5 Auto Tuning Functions...
Page 151: ...6 Application Functions...
Page 185: ...7 Protective Functions...
Page 224: ...Protective Functions 7 40 Blank page...
Page 225: ...8 Advanced Safety Functions...
Page 230: ...Advanced Safety Functions 8 6 When test pulse is used Duplex safety input Safety input...
Page 245: ...9 List of Parameters...
Page 281: ...10 Timing Chart...
Page 290: ...Timing Chart 10 10 Blank page...
Page 291: ...11 Power Supply Module...