4-3-2 Speed coincidence output (V-COIN)
This signal is output when the motor speed is equal to the velocity specified by the velocity command. The motor
speed is judged to be coincident with the specified speed when the difference from the velocity command before/after
acceleration/deceleration is within the range specified by Pr 4.35 “Speed coincident range”
■ Parameters
Class
No.
At-
trib-
ute *1)
Title
Range
Unit
Function
4
35
A
Speed
coincidence
range
10
–
20000
r/min
Set the speed coincidence (V-COIN) output detection timing. Output
the speed coincidence (V-COIN) when the difference between the
speed command and the motor speed is equal to or smaller than the
speed specified by this parameter.
The detection response has 10 r/min hysteresis.
*1) For parameter attribute, refer to Section 9-1.
*1 Because the speed coincidence detection is associated with 10 r/min hysteresis, actual detection range is as shown
below.
Speed coincidence output OFF ON timing (Pr 4.35 – 10) r/min
Speed coincidence output ON OFF timing (Pr 4.35 + 10) r/min
Speed coincidence
outputV-COIN
ON
ON
OFF
Speed [r/min]
OFF
Motor velocity
Pr 4.35 *1
[Speed coincidence
range]
Pr 4.35 *1
(Speed coincidence range)
Velocity
command
Pr 4.35 *1
(Speed coincidence range)
Velocity command after
acceleration/deceleration process
Time
R1.05