No. SX-DSV02472 -
20-
3-2 7-segment LED
Station alias value set with RSW will be displayed at power-UP, after that, the setting contents of Pr 7.00 (LED
display) will be displayed.
Upon occurrence of an alarm, set of alarm codes (main and sub, alternately) is displayed. Upon occurrence of warning,
the warning code will be displayed.
■ Parameters
Class No.
At-
trib-
ute *1)
Title
Range
Unit
Function
7
00
A
Information on
LED
0–32767
—
Selects the information displayed on 7-SEG LED display.
7
01
R
Address display
time upon power up
0–1000
100 ms
Sets Station alias(Lower) display (NOTE) time upon turning the
control power ON.
When the setting value is 0 to 6, it is processed in 600ms.
(NOTE) In the case of Pr7.41(Station alias selection)=1, although
SII's setting value is used to Station alias, even in this
case, display the setting value of the rotary switch.
*1) For parameter attribute, refer to Section 9-1.
Pr 7.00
Information on
display
Remarks
0
Normal display
[-]: servo OFF, [00]: servo ON
1
Mechanical angle
Range: 0 to FFF hex.
0: zero position of 1 revolution data of encoder.
Data increments as motor turns CCW.
When the displayed value exceeds [FF], the count is reset to [0] and restarted.
When the incremental encoder is used, upon turning the control power ON, [nF] (not Fixed) is
displayed until zero position of the encoder is detected.
2
Electrical angle
Display range: 0 to FF hex.
0: the position where U phase induced voltage reaches the positive peak.
Data increments as motor turns CCW.
When the displayed value exceeds [FF], the count is reset to [0] and restarted.
5
Encoder
Accumulated
communication
error counts
Display range: 0 to FF hex.
Max. accumulated communication error counts: FFFF hex.
Only the least significant byte is displayed.
When the displayed value exceeds [FF], the count is reset to [00] and continue counting.
* Accumulated communication error counts will be cleared upon turning the control power OFF.
6
External scale
Accumulated
communication
error counts
(Not Supported)
4
Station alias value
(Rotary switch
setting)
Lower 8bits of station alias value that set by rotary switch at power ON is displayed. This value is not
change after power ON.
Station alias is 0 to F[hex], the display is one-digit. Station alias is upper than 10[hex], the display is
two-digit.
In the case of Pr7.41(Station alias selection)=1, although SII's setting value is used to Station alias,
even in this case, display the setting value of the rotary switch.
7
External scale
Z phase counter
(Not Supported)
When the incremental external scale is used in full closed control, displays the value of Z
phase counter read from external scale: 0
−
F hex.
* This displayed value is not affected by the value of Pr 3.26 Reversal of direction of external scale.
This function is effective only in the case of the serial incremental external scale and in the external
scale of the A/B/Z phase, “nA” (not Available) is indicated.
Other
To be used by the
manufacturer but
not by the user.
—
R1.05