4.8.
Removal of Thermo Protector
1. Remove the Thermo Protector.
* The Thermo Protector is supplied as an assembly
with an ON/OFF Switch Unit (with Thermo Protector
and Fuse).
Fig.17
4.9.
Removal of Cord Reel Partition
Unit
1. Remove the Cord Reel Partition Unit from the Lower
Body by holding its rear side and lifting it up in a backward
direction.
2. Cut the Lead Wires at the base of the Wire Connector.
Fig.18
※
Use the dedicated tool to crimp the crimp contact.
Assembling:
When replacing the Cord Reel Partition Unit with a new
one, connect it using Wire Connector CE-230 and wrap
Gasket V (Glass Tape) around it.
4.10. Removal of Cord Reel Unit
1. Press the Brake Lever Unit of the Cord Reel Partition Unit
to unwind spare turns.
Fig.20
2. Remove the center screw and remove the Cord Reel
Unit.
Fig.21
Assembling:
* When replacing the Cord Reel Unit with a new one, place
it in the Body Partition in the reverse order of disassembly
by screwing it.