Panasonic MA3J741 (MA741) Specifications Download Page 1

Schottky Barrier Diodes (SBD)

1

Publication date: April 2004

SKH00054BED

MA3J741 

(MA741)

Silicon epitaxial planar type

For switching

Features

Mini type of MA3X704A (MA704A)

Low forward voltage V

F

 and good wave detection efficiency 

η

Small temperature coefficient of forward characteristic

Small reverse current I

R

Absolute Maximum Ratings  

T

a

 

=

 25

°

C

Parameter

Symbol

Rating

Unit

Reverse voltage

V

R

30

V

Maximum peak reverse voltage

V

RM

30

V

Forward current

I

F

30

mA

Peak forward current

I

FM

150

mA

Junction temperature

T

j

125

°

C

Storage temperature

T

stg

55 to

 +

125

°

C

Internal Connection

Marking Symbol: M1L

Parameter

Symbol

Conditions

Min

Typ

Max

Unit

Forward voltage

V

F1

I

F

 

=

 1 mA

0.4

V

V

F2

I

F

 

=

 30 mA

1.0

Reverse current

I

R

V

R

 

=

 30 V

300

nA

Terminal capacitance

C

t

V

R

 

=

 1 V, f 

=

 1 MHz

1.5

pF

Reverse recovery time 

*

t

rr

I

F

 

=

 I

R

 

=

 10 mA

1.0

ns

I

rr

 

=

 1 mA, R

L

 

=

 100 

Detection efficiency

η

V

IN

 

=

 3 V

(peak)

 ,  f = 30 MHz

65

%

R

L

 

=

 3.9 k

, C

L

 

=

 10 pF

Electrical Characteristics

  T

a

 

=

 25

°

±

 3

°

C

1

2

3

Bias Application Unit (N-50BU)

90%

Pulse Generator
(PG-10N)
R

s

 

50 

Wave Form Analyzer
(SAS-8130)
R

i

 

50 

t

p

 

µ

s

t

r

 

0.35 ns

δ = 

0.05

I

F

 

=

 10 mA

I

R

 

=

 10 mA

R

L

 

=

 100 

10%

Input Pulse

Output Pulse

I

rr

 

=

 1 mA

t

r

t

p

t

rr

V

R

I

F

t

t

A

1 : Anode
2 : N.C.
3 : Cathode
EIAJ: SC-79

SMini3-F1 Package

Unit: mm

0.3

2.0

±

0.2

1.3

±

0.1

(0.65)

1

3

2

(0.65)

0.9

±

0.1

2.1

±

0.1

1.25

±

0.1

0 to 0.1

(0.15)

(0.425)

+0.1

–0

0.15

+0.1

–0.05

Note) 1. Measuring methods are based on JAPANESE INDUSTRIAL STANDARD JIS C 7031 measuring methods for diodes.

2. This product is sensitive to electric shock (static electricity, etc.). Due attention must be paid on the charge of a human body

and the leakage of current from the operating equipment.

3. Absolute frequency of input and output is 2 GHz.

4.*: t

rr

 measurement circuit

Note) The part number in the parenthesis shows conventional part number.

This product complies with the RoHS Directive (EU 2002/95/EC).