Installation and Operating Instructions

Video Intercom System — Lobby Station

Model No.    

VL-VN1900

Thank you for purchasing a Panasonic product.
Please follow all instructions in this document and save it for future reference.
Carefully read the information found in the section titled "2.1  Important safety information" in particular.

This system is an auxiliary system; it is not designed to provide complete protection from property loss.
Panasonic will not be held responsible in the event that property loss occurs while this system is in operation.

Note to the installer

R

This document includes instructions for both installation and operation. See the section titled
"4  Installation" for installation instructions.

R

Please read this document carefully, and install the product safely and correctly by following the
instructions.

R

Only use attachments/accessories specified by the manufacturer.

R

The installation shall be carried out in accordance with all applicable installation rules.

Summary of Contents for LST 116

Page 1: ...ide complete protection from property loss Panasonic will not be held responsible in the event that property loss occurs while this system is in operation Note to the installer R This document includes instructions for both installation and operation See the section titled 4 Installation for installation instructions R Please read this document carefully and install the product safely and correctl...

Page 2: ... 12 4 Installation 4 1 Installation cautions 13 4 2 Installing the power supply unit 13 4 3 Installing the lobby station 15 4 4 Wiring schematic 21 4 5 Wire and cable specifications 22 4 6 Connecting other devices 23 5 Programming 5 1 Programming overview 24 5 2 PC programming 24 5 3 Lobby station management 27 6 Basic operations 6 1 Lobby station operations 30 6 2 Facility staff operations using ...

Page 3: ...nected to each lobby station R Supports multi building installations and buildings with up to 99 floors Easy to configure and maintain R System settings can be configured in advance using a computer and uploaded on site over the network R Detailed settings and logs can be accessed using a web browser Convenient features for residents visitors and facility staff R The system can be used in room mod...

Page 4: ...R2 R3 1 2 B A F H I J K L G D C M Facility staff office Fully expanded system example up to 2000 SIP devices 1 requires control box R1 R2 R3 1 2 R1 R2 R3 1 2 Facility staff office Control box E 1 SIP devices include lobby stations room monitors door stations and SIP phones 4 1 Introduction ...

Page 5: ...1 per door station 7 1 Up to a combined total of 8 lobby station and door station cameras can be registered to a room monitor for easy camera monitoring 2 If room monitors and door stations are not powered by Power over Ethernet PoE a power supply unit is required 3 Up to 256 rooms can have multiple room monitors All other rooms can have only one room monitor For more information refer to the docu...

Page 6: ...remove the ferrite core 1 4 pin terminal block Used to connect wires to the K IN connection terminals 1 3 pin terminal block Used to connect wires to the K OUT connection terminal 1 1 3 Optional items The following items are sold separately Please contact your nearest Panasonic dealer for sales information Compatible system devices as of March 2017 Item Model no Door Station IP compatible door sta...

Page 7: ...aning Enter the room number and then press the M N button Terms and illustrations R Model number suffixes e g the BX in VL VN1900BX are omitted unless necessary R Design and specifications are subject to change without notice R Illustrations may vary slightly from the actual product Trademarks R The software of this product is based in part on the work of the Independent JPEG Group R Microsoft and...

Page 8: ...g places Places where the product and power supply unit may be splashed with water or chemicals Places where there is a high concentration of dust or high humidity R Do not push any objects through the openings of the product R If any of the following conditions occur disconnect the Ethernet LAN cable from the product disconnect the power supply unit from the power outlet and then refer servicing ...

Page 9: ...en configuring email addresses room numbers or other contact information make sure all information is entered correctly Incorrect information could cause user information to be disclosed to unintended recipients R Protect user information when sending the product to be repaired or when handing it over to a third party Use the product s reset function to initialise the product before when sending t...

Page 10: ...es with recycling systems A B These symbols A B on the products packaging and or accompanying documents mean that used electrical and electronic products and batteries must not be mixed with general household waste For proper treatment recovery and recycling of old products and batteries please take them to applicable collection points in accordance with your national legislation By disposing of t...

Page 11: ... collection centres etc or call the toll free number below Website http www panasonic com in corporate sustainability panasonic india i recycle program html Service helpline 1800 103 1333 or 1800 108 1333 2 9 For Europe Declaration of Conformity Panasonic Corporation declares that the radio equipment type VL VN1900BX VL VN1900EX is in compliance with Directive 2014 53 EU The full text of the EU de...

Page 12: ...e Search buttons M N and M N Used to select items shown on the display Cancel button M N Call button M N Camera lens adjustment lever K OUT connection terminals output Used to send signals to an electric lock DC IN connector Used to connect the lobby station to the power supply unit Vandal proof button See 4 3 5 Information about the vandal proof feature Page 20 LAN connector Used to connect the l...

Page 13: ... user supplied See 4 5 Wire and cable specifications Page 22 for specifications Soldering gun and solder insulation sleeve user supplied Installation location R The device must be installed inside an electrical panel or cabinet R A readily accessible disconnect device shall be incorporated external to the equipment The external disconnect device must be certified and have a creepage and clearance ...

Page 14: ...top and bottom on the power supply unit A B B D C A Terminal screws B Cable binders connected to cable binder holes C To lobby station D To AC power outlet R Recommended torque AC IN terminals 0 5 N m 5 1 kgf cm DC IN terminals 0 45 N m 4 6 kgf cm 5 Strip the remaining ends of the DC wires as shown 25 mm 7 mm A A To DC terminals of power supply unit 6 Solder the ends of the DC wires to the DC plug...

Page 15: ...ler and open door sensor user supplied See 4 5 Wire and cable specifications Page 22 for specifications Installation location R Do not install the product in the following locations There may be a risk of malfunction or communication disturbances Places where vibration impact or echoing occurs Places near a high concentration of dust hydrogen sulphide ammonia sulphur or noxious fumes Places where ...

Page 16: ...slanted surface side view Camera height 1020 mm Surface angle 60 Camera lens angle 0 500 mm 1020 mm 60 1320 mm 2280 mm 960 mm 72 A B Camera height 1000 mm Surface angle 45 Camera lens angle 15 2320 mm 500mm 1000 mm 45 1380 mm 940 mm 72 A B Top view 500 mm 120 1730 mm A Note R The measurements and angles shown here are for reference purposes and may vary depending on the environment R The angle of ...

Page 17: ...ss all necessary cables and wires DC plug LAN cable wires for electric lock access controller open door sensor through the knockout holes 3 Install the flush mount box in the wall 4 Attach the vandal proof post to the back of the lobby station R See 4 3 5 Information about the vandal proof feature Page 20 for information about the vandal proof feature B C A A Screws B Bracket C Vandal proof post 1...

Page 18: ...he hex wrench to secure the lobby station to the flush mount box using the 4 screws R We recommend you view the lobby station s camera image using a room monitor and adjust the camera lens angle before completing the lobby station installation See 4 3 4 Adjusting the camera lens angle Page 20 R Do not cover the water drain holes A A Water drain holes 18 4 Installation ...

Page 19: ...om pulling out R Make sure the 3 pin terminal block snaps into place and is securely connected to the K OUT connection terminals 5 Insert the wires from the access controller and open door sensor into the 4 pin terminal block tighten the terminal block screws and then attach the terminal block to the K IN connection terminals R Connect the wires as follows C1 and C2 Access controller C3 and C4 Ope...

Page 20: ...ion is installed in the flush mount box If there is an attempt to remove the lobby station from the flush mount box the post releases the button and the vandal proof feature sounds an alert for 3 minutes Note R If this alert is triggered accidentally during installation or to avoid false detections when performing maintenance disconnect the lobby station from the power supply by disconnecting the ...

Page 21: ...hing hub Switching hub A A D A B To AC power outlet 24 V DC POWER SUPPLY UNIT B C A A 12 V AC DC R2R1 RELAY BOX Electric lock output Access controller input Power supply Electric lock 12 V AC DC LAN cable If the switching hub does not support PoE a power supply unit VL PS240 sold separately is required When connecting an electric lock user supplied a relay box VL RLY1 sold separately is required C...

Page 22: ...m 24 AWG According to specification of connected device 1 2 mm 17 AWG Note the following when selecting wiring R For all wiring except network wiring use 2 conductor solid copper wiring with a PE polyethylene insulated PVC jacket Mid capacitance non shielded wiring is recommended R A certified power supply wiring has to be used with this equipment The relevant national installation and or equipmen...

Page 23: ...or to each lobby station via the K IN connection terminals An open door sensor works together with the electric lock It allows the lobby station to send a signal to the electric lock continuously until the door is open R One open door sensor can be connected to each lobby station 4 6 4 SIP phones You can connect SIP phones to the network to be used in the facility staff office common areas etc R U...

Page 24: ...he MAC address of individual devices etc 3 Generate Use the setup tool to generate configuration files from the information you ve specified in the previous steps This information is saved on the computer and will be automatically distributed to each lobby station door station and room monitor later 4 Deploy If using a control box make sure it is configured and running and then send the configurat...

Page 25: ...figuration files based on the data you have configured using the setup tool Each device can then download its configuration file when it is first turned on 4 Downloading Data to Device Allows the setup tool to host the configuration files so that each device can then download its configuration file when it is first turned on 5 Check and Confirmation Allows you to confirm which devices have success...

Page 26: ...register each device s MAC address using the setup tool Follow the prompts displayed on the lobby station or room monitor and enter the device s room number Each device will download its configuration file from the computer and perform its own initial setup Note that for door stations you must register each door station s MAC address using the setup tool in order for the door station to be able to...

Page 27: ...gement 1 Press M N enter the administrator password M N R The default administrator password is 135246 2 Select Change Password M N 3 Enter the desired 6 digit code M N 4 For confirmation re enter the desired 6 digit code M N 5 3 1 Issuing access cards Authentication is required in order to issue access cards To authenticate you can use either the administrator s access card or the password used t...

Page 28: ...tion mode is enabled Visitor calls are directed to a receptionist Reception Mode Off Room mode is enabled Visitor calls can call rooms directly Note R If Not registered is displayed no SIP phones are registered therefore reception mode is unavailable Changing the receptionist 1 Press M N enter the administrator password M N R The default administrator password is 135246 2 Select Reception Mode M N...

Page 29: ... access the lobby station via web programming 80 Change Password Allows facility staff to change the administrator password which is used to access lobby station management R See Changing the administrator password Page 27 Language Allows facility staff to change the display language used by the lobby station English Reception Mode Allows facility staff to switch the lobby station between room mod...

Page 30: ...hone 6 2 1 Opening a lobby door While talking to a visitor at a lobby station dial M N enter the open door code M N R The code is specified by the system administrator The default code is M0N M0N M0N 6 2 2 Switching between room mode and reception mode While talking to a lobby station dial M N M N enter the mode switching code M N R The code is specified by the system administrator The default swi...

Page 31: ...r or when calling from a common lobby station such as a lobby station that is installed at a guard house or at an entrance gate CALLING INSTRUCTIONS MBuilding nameN M N MRoom numberN M N R Example To call building A room 101 M N M N M1N M0N M1N M N To call building 3 room 101 M3N M N M1N M0N M1N M N R For building numbers B F use the M N button Press the button repeatedly without stopping to advan...

Page 32: ... and are connected to the correct terminals 19 R The switching hub is not connected or not turned on Make sure switching hubs or any other necessary network equipment is connected properly and turned on R The system devices lobby stations room monitors door stations etc are not connected or not turned on Make sure all devices are connected properly and turned on General issues Problem Cause Soluti...

Page 33: ...rating Compliant with IK07 Card reader RFID ISO IEC 14443 Type A MIFARE Frequency 13 56 MHz RF transmission power 42 dBµA m max 10 m Video format H 264 codec Audio format G 711 codec Network interface Ethernet II DIX Network protocol TCP IP UDP Communication mode Speed Duplex AUTO 10BASE T 100BASE TX FULL HALF Auto negotiation 1 Water resistance is only assured if the product is installed correctl...

Page 34: ...L and other conditions Please read all licence information and copyright notices related to the open source software used by this product This information is available at the following web page http panasonic net pcc support intercom vn1900 At least three 3 years from delivery of this product Panasonic Corporation will give to any third party who contacts us at the contact information provided bel...

Page 35: ...35 Notes ...

Page 36: ... Panasonic Corporation 2017 1006 Oaza Kadoma Kadoma shi Osaka 571 8501 Japan http www panasonic com PNQP1317YA C0317MG1067 ...