background image

Thank you very much for purchasing Panasonic products. Read this Instruction 

Manual carefully and thoroughly for the correct and optimum use of this product.

Kindly keep this manual in a convenient place for quick reference.


Never use this product as a sensing device for personnel protection.

In case of using sensing devices for personnel protection, use 

products which meet laws and standards, such as OSHA, ANSI or 

IEC etc., for personnel protection applicable in each region or country.

Although this product corresponds to a Class 1 laser product, it is 

dangerous to see the laser beam which has been passed through a 

viewing optical system such as a lens etc. Hence, please avoid this.

Use of control or adjustment or performance of procedures other 

than those specified in this instruction  manual  may result in 

hazardous radiation expose.

WARNING

CAUTIONS

3

This product has been designed to meet the specifications when it is used 

along with the optional exclusive amplifier. If an amplifier other than the 

exclusive amplifier is used, not only the specifications may not be met, but it 

may also be a cause for malfunction or break down. Hence, please ensure to 

use this product along with the optional exclusive amplifier.








This product has been developed / produced for industrial use only.

Always use the sensor with the connector to be joined to the amplifier.

Make sure that the power is off while wiring to the amplifier.

In case noise generating equipment (switching regulator, inverter motor etc.) 

is used in the vicinity of this product, connect the frame ground (F.G.) 

terminal of the equipment to an actual ground.

If power is supplied from a commercial switching regulator, ensure that the 

frame ground (F.G.) terminal of the power supply is connected to an actual 

ground.

Do not use the sensor during the initial transient time (0.5 sec.) just after the 

power supply is switched on.

Do not run the wires together with high-voltage lines or power lines or put 

them in the same raceway. This can cause malfunction due to induction.

Take care that the sensor head is not directly exposed to fluorescent lamp 

from a rapid-starter lamp or a high frequency lighting device, as it may affect 

the sensing performance.

The sensor head cable cannot be extended.

Make sure that stress is not applied directly to the sensor head cable joint.

This sensor is suitable for indoor use only.

Do not allow any water, oil fingerprints, etc., which may refract light, or dust, 

dirt, etc., which may block light, to stick to the emitting / receiving surfaces of 

the sensor head. In case they are present, wipe them with a clean, soft cloth 

or lens paper.

Do not use the sensor in vaporous, dusty or corrosive gas atmospheres.

Take care that the sensor does not come in contact with water, oil, grease or 

organic solvents, such as, thinner, etc.

Make sure that the power is off while cleaning the emitting / receiving 

windows of the sensor head.

SPECIFICATIONS

2

Notes: 1) 

2)

The model No. of retroreflective type sensor with the suffix '

-Y

' is the sensor without the 

RF-330

reflector. Arrange the reflector separately.

(e.g.) 

LS-H91F-A-Y

Configure the mode settings in the applicable amplifier 

LS-400

 series.

Diffuse reflective type

30 to 150mm
30 to 150mm
30 to 250mm
30 to 500mm

LS-H21F-A

Connector for amplifier: 1 pc.

Explanation label (JIS) :  1 pc.

Type

Coaxial retroreflective type

Sensing

range

(Note 2)

0.1 to 1m

H-SP mode

0.1 to 1m

FAST mode

0.1 to 3m

STD mode

0.1 to 5m

U-LG mode

LS-400

 series

Applicable amplifier

Model No.

Item

LS-H91F-A 

(Note 1)

Connector for amplifier: 1 pc.

RF-330

 (Reflector): 1 pc.

Explanation label (JIS) :  1 pc.

Accessories 

30g approx.

Weight

0.1mm

2

 shielded cable, 2m long

Cable

Enclosure: PBT (Attachment: PEI), Lens cover: Acrylic

Material

Red semiconductor laser Class 1 (FDA / IEC / JIS standard)

(Max. output: 1mW or less, Peak emission wavelength: 655nm)

Emitting element

-10 to 

+

55

℃ 

(No dew condensation or icing allowed),  Storage: -20 to 

+

70

35

85% RH, Storage: 35

85% RH

Ambient humidity

Ambient temperature

Green LED (Lights up when laser is emitted)

Laser emission indicator

Orange LED (Lights up when amplifier output is ON)

Operation indicator

INSTRUCTION MANUAL

LS-H

F-A

Conforming to FDA

Laser Sensor Head

MJE-LSHFA No.0059-45V

Laser emission indicator (green)

While laser is emitted, the laser emission indicator (green) of the sensor head 

lights up.

This indicator is visible even when wearing laser protective glasses.

Operation indicator (Orange)

Laser emission indicator (Green)

Direction of

laser emission

FOR SAFE USE OF A LASER PRODUCT

1

With regard to safety of laser products, IEC 60825-1

-2014

 'Safety of laser 

products' has been stipulated by the IEC (International Electrotechnical Commis-

sion). In IEC 60825-1

-2014

, laser products are divded into classes corresponding 

to the degree of danger of the laser component, and preventive measures to 

assure safety which should be taken with each class are stipulated. 

This product is classified as a '

Class 1 laser product

' by IEC 60825-1

-2014

This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated 

June 24, 2007, issued by CDRH (Center for Devices and Radiological Health) under 

the FDA (Food and Drug Administration). For details, refer to the Laser Notice No. 50.

Classification of laser product (IEC 60825-1

-2014

)

Safe under reasonably foreseeable conditions.

Class 1

Description of hazard class 

Classification

Summary of the safety precautions for user of a laser product (IEC 60825-1

-2014

)

The following labels are affixed on this product in accordance with the FDA 

and IEC 60825-1

-2014

 standard.

Warning label

<Label position>

(Label based on IEC 60825-1

-2014

)

(Label based on FDA

)

Note: When this product is used based on JIS / IEC standard, affix the accessory explanation label 

on the 'Label based on FDA'.

Direction

of laser

emission

Direction

of laser

emission

Training

Emission indicator 

device
Warning signs
Beam path 
Specular reflection 
Eye protection 
Protective clothing 

Not required

Not required

Not requirements

No requirements

No requirements

No requirements

Not required

Not required but recommended for applications that involve direct 

viewing of the laser beam

1

Beam attenuator 

protection

Laser safety officer 

Class

Not required

Remote interlock

Not required

Not required

Key control

Note:  This table is intended to provide a convenient summary of precautions. See text of IEC 

standard for complete precautions.