286
Replacement of fuse
Replace fuse of the controller when blowing.
The power of the laser marker cannot be turned on if the fuse is blown.
⿎
Models of replacement parts
Depending on the manufactured period of the laser marker, the available parts model of the fuse is vary. Check the ampere
rating printed on the fuse holder part of the controller rear side and select the appropriate model form this table. If the user
applies any other fuses than the specified one, failure might result.
Applicable laser marker
Type
Model
LP-400 series
Time Lag Fuse (Rating: 250V 10A)
0215010
(made by Littelfuse)
Type A of PSE (Rating: 250V 15A)
GAB 250V 15
(made by Daito Communication Apparatus Co., Ltd)
LP-V series
LP-W series
Time Lag Fuse (Rating: 250V 6.3A)
021506.3MXP (made by Littelfuse)
B Type Brown Glass Fuse (Rating:
250V 15A)
FGBO 250V15APBF (made by FUJI TERMINAL
INDUSTRIES Co., LTD)
⿎
Steps for replacement
1.
Remove causes for fuse blowing.
2.
Turn OFF the key switch of the controller, and disconnect the controller power cable.
3.
Turn the fuse holder on the back side, and remove the
fuse.
4.
Replace it with new one.
5.
Turn the fuse holder, and install the fuse.
Replacement of cable
If the cable connecting the head and controller is broken because of the usage conditions and installation environment, it
needs to be replaced.
⿎
Models of replacement parts
For details of purchasing cables, contact our sales office.
Type
Model
Head Power Cable
LP-ACP20-5
Head Control Cable
LP-ACS20-5
⿎
Steps for replacement
Refer to Operation/Maintenance Manual “2-2 Connecting Laser Marker” (P.72), and connect cables.
Fuse Holder
LP-400 Series
LP-V/LP-W Series
ME-LP400V-OP-6
Summary of Contents for LP-V Series
Page 11: ...11 MEMO ME LP400V OP 6 ...
Page 32: ...32 1 Product Overview ME LP400V OP 6 ...
Page 58: ...2 Installation and Connection ME LP400V OP 6 ...
Page 77: ...3 Basic Operation Procedure ME LP400V OP 6 ...
Page 121: ...4 Description of Operation Screen ME LP400V OP 6 ...
Page 146: ...146 Symbol ME LP400V OP 6 ...
Page 271: ...271 MEMO ME LP400V OP 6 ...
Page 272: ...Maintenance ME LP400V OP 6 ...
Page 291: ...Troubleshooting ME LP400V OP 6 ...
Page 308: ...Appendix ME LP400V OP 6 ...
Page 328: ...Index ME LP400V OP 6 ...
Page 333: ...No 9000 0062 14V ...
Page 334: ... Panasonic Industrial Devices SUNX Co Ltd 2003 2018 July 2018 9000 0062 14V ...