4-12 Trigger Setting
This function is used for setting of marking for the moving object (on-the-fly marking) and marking timing.
The trigger setting is specified on this screen, depending on the status of work to be marked (flying or still).
The screen also sets the timing of starting marking after input of trigger signal.
4-12-1 Marking to Static Work
1
2
Description
1
Moving Direction
Selects “STILL.” for the moving direction.
2
Delay Time :
Sets the time difference from the input of trigger signal to marking start.
Setting Range
0 to 5000 ms
Reference
•
Set a delay time shorter than a input interval of trigger signal.
•
When the next trigger signal is inputted during delay, warning (E800) occurs. (Only if “Detect TRIG. Warning during
Marking” in Environment Setting is valid.)