214
4-11 Laser Setting
The laser setting screen specifies the adjustment for laser marker, such as the setting of laser power and scan speed, and
marking quality control.
4-11-1 Setting Parameters
1
3
4
5
7
8
9
10
11
12
6
2
Description
1
Laser Power :
Sets the output level of laser power.
Setting Range
0.5 to 100.0
Reference
•
Set the laser power in increments of 0.5.
•
The laser power gradually decreases due to the degradation of laser.
Do not use it with the initial value of 100.
2
Scan Speed :
Specifies the traveling speed of laser on the marking surface.
Setting Range
1 to 12000 mm/s (LP-430 / LP-420 / LP-410 / LP-435 / LP-425 /LP-V10 / LP-V15)
1 to 6000 mm/s
(LP-431 / LP-421 / LP-411 / LP-W052)
CAUTION
• If too high laser power is set or too slow scan speed is set, it may flame up or
burn depending on the material to be used for the marking. At test marking,
radiate the laser by setting rather low laser power and rather fast scan speed,
check the marking quality, and adjust the setting value gradually.
3
Laser Pulse Cycle (Only LP-V / LP-W series) :
•
LP-V Series : Adjusts the interval of pulse pumping of the laser. When setting larger value for the pulse cycle,
the peak power becomes higher. Note that when setting larger value for the pulse cycle, the line tends to be
marked in dot line after scanning with high speed.
•
LP-W Series : It is valid when duty is set to other than 100%.The time which laser is radiation is ON/OFF during
one laser pulse cycle.
Setting Range
10.0 to 50.0μs
(LP-V10 / LP-V15)
50 to 1000μs
(LP-W052)
ME-LP400V-OP-6
Summary of Contents for LP-V Series
Page 11: ...11 MEMO ME LP400V OP 6 ...
Page 32: ...32 1 Product Overview ME LP400V OP 6 ...
Page 58: ...2 Installation and Connection ME LP400V OP 6 ...
Page 77: ...3 Basic Operation Procedure ME LP400V OP 6 ...
Page 121: ...4 Description of Operation Screen ME LP400V OP 6 ...
Page 146: ...146 Symbol ME LP400V OP 6 ...
Page 271: ...271 MEMO ME LP400V OP 6 ...
Page 272: ...Maintenance ME LP400V OP 6 ...
Page 291: ...Troubleshooting ME LP400V OP 6 ...
Page 308: ...Appendix ME LP400V OP 6 ...
Page 328: ...Index ME LP400V OP 6 ...
Page 333: ...No 9000 0062 14V ...
Page 334: ... Panasonic Industrial Devices SUNX Co Ltd 2003 2018 July 2018 9000 0062 14V ...