136
4-6-1 Dual pointer
Dual pointer shows the rough indication of the work distance (distance from the head base to the marking surface). It
displays the red point emitted in oblique and the red cross emitted perpendicularly from the head. The distance where the
laser point is closest to the center of the cross represents the guide of the work distance.
Depending on the required marking quality or installation condition including the focus adjustment usage, the dual pointer
may shows not always the appropriate work distance. Confirm the marking quality with the work distance indicated by the
dual pointer and adjust it accurately as appropriate.
Notice
• Use the dual pointer only as the guideline. For obtaining the appropriate marking quality, fine adjust the distance from
the work after marking on an actual object and referring to its marking positions.
1.
Press [INDICATE].
2.
Select [Dual Pointer], and press [START].
3.
The dual pointer is disappeared by pressing [STOP].
The guide indication is stopped automatically after 1 minute.
Reference
• The dual pointer is adjusted according to the distance from the work defined at the factory. When the work distance is
changed by the focus adjustment function, dual pointer does not move with this function, so it cannot be used as the
work distance guide.
ME-LP400V-OP-6
Summary of Contents for LP-V Series
Page 11: ...11 MEMO ME LP400V OP 6 ...
Page 32: ...32 1 Product Overview ME LP400V OP 6 ...
Page 58: ...2 Installation and Connection ME LP400V OP 6 ...
Page 77: ...3 Basic Operation Procedure ME LP400V OP 6 ...
Page 121: ...4 Description of Operation Screen ME LP400V OP 6 ...
Page 146: ...146 Symbol ME LP400V OP 6 ...
Page 271: ...271 MEMO ME LP400V OP 6 ...
Page 272: ...Maintenance ME LP400V OP 6 ...
Page 291: ...Troubleshooting ME LP400V OP 6 ...
Page 308: ...Appendix ME LP400V OP 6 ...
Page 328: ...Index ME LP400V OP 6 ...
Page 333: ...No 9000 0062 14V ...
Page 334: ... Panasonic Industrial Devices SUNX Co Ltd 2003 2018 July 2018 9000 0062 14V ...