111
4-4-3 Interlock terminal rating and I/O circuit
This section shows the following interlock terminals and I/O circuit loaded onto the I/O terminal block.
Interlock input terminals:
Interlock monitoring terminals:
INTERLOCK 1(+) (X16)
INTERLOCK 1 MONITOR (Y16)
INTERLOCK 1(-) (X17)
INTERLOCK 1 MONITOR COM. (Y17)
INTERLOCK 2(+) (X18)
INTERLOCK 2 MONITOR (Y18)
INTERLOCK 2(-) (X19)
INTERLOCK 2 MONITOR COM. (Y19)
ワㄐㄕㄊㄆ
• INTERLOCK terminals (X16, X17 and X18, X19) are connected to the operating coil of the internal contactor in the
controller. Connect INTERLOCK (+) and INTERLOCK (-) with the non-voltage contact (dry contact) such as a relay or a
switch. Do not connect with the voltage contact such as a transistor.
Pin X16 INTERLOCK 1 (+)
ヌビフヷチュヤ
ヌビフヷチュヤ
Pin X17 INTERLOCK 1 (-)
Pin X18 INTERLOCK 2 (+)
Pin X19 INTERLOCK 2 (-)
Pin Y16 INTERLOCK 1 MONITOR
Pin Y17 INTERLOCK 1 MONITOR COM.
Pin Y19 INTERLOCK 2 MONITOR COM.
Pin Y18 INTERLOCK 2 MONITOR
ヒパパㄎモ
ヒパパㄎモ
Contact
capacity:
1A 24V DC
Contact
capacity:
1A 24V DC
Contactor
Contactor
Laser oscillator
power
ンㄆㄇㄆㄓㄆㄏㄆ
• For the connection examples of the interlock terminals, refer to “4-5-4 Connection example of interlock terminals and
laser stop terminals” (P.114).
• INTERLOCK 1(+) (X16) and INTERLOCK 2(+) (X18) are connected to the interlock dedicated power 24DVC
internally. This power supply is independent from 24V OUT (X1, Y3) in I/O terminal.
ME-LPRH-SM-3
Summary of Contents for LP-RH Series
Page 19: ...1 Product Overview ME LPRH SM 3...
Page 42: ...2 Laser Marker Installation ME LPRH SM 3...
Page 68: ...3 Operation Method ME LPRH SM 3...
Page 90: ...4 External Control Using I O ME LPRH SM 3...
Page 138: ...5 External Control by Communication Commands ME LPRH SM 3...
Page 147: ...6 Link Control with External Devices ME LPRH SM 3...
Page 172: ...7 Maintenance ME LPRH SM 3...
Page 201: ...Troubleshooting ME LPRH SM 3...
Page 236: ...Index ME LPRH SM 3...
Page 239: ......