46
■ Marking character string (ASCII code specified) : MCS
Sets the marking character string by ASCII code. (For alphanumeric and symbols only)
Setting / Readout data of marking character string
STX
MCS
Sub
command
[Line No.] [Marking character string]
Max. 32-byte
(Check sum)
Delimiter
Sub command is “S” at the time of setting and “A” for response data at the time of readout.
Readout request of marking character string
STX
MCS
R
[Line No.]
2-byte
(Check sum)
Delimiter
Name
Data length
[byte]
Description
Remarks
Line No.
2
“01”–“99” [row]
Marking
character string
Max. 30
Characters within the range from 20 (HEX)
to 7E (HEX) of ASCII code
(functional characters should not be
included)
Specify 0-byte to the character string to
be deleted.
Reference
•
If readout data includes function characters (such as “%SFT:0”), the setting character (“%SFT:0”) is read out, but
characters to be actually marked are not.
•
If readout data includes characters that cannot be expressed in ASCII code such as Katakana and Kanji (2-byte
character), only these 2-byte characters are read out in shift-JIS code. In this case, the maximum readout data will be
32-byte or more.
■ Marking character string (Shift-JIS code specified) : STR
Sets the marking character string by shift-JIS code. (For characters including KANA, KANJI and function characters)
Setting / Readout data of marking character string
STX
STR
Sub
command
[Line No.] [Marking character string]
Max. 62-byte
(Check sum)
Delimiter
Sub command is “S” at the time of setting and “A” for response data at the time of readout.
Readout request of marking character string
STX
STR
R
[Line No.]
2-byte
(Check sum)
Delimiter
Name
Data length
[byte]
Description
Remarks
Line No.
2
“01”–“99” [row]
Marking
character string
Max. 60
The character string (Up to 30 characters) to be
set in the specified line is specified with shift-JIS
code. (However, the function character should be
specified by ASCII code.) Specify 0-byte to the
character string to be deleted.
See the next page.
ME-LPMSZ-SR-9
Summary of Contents for LP-M Series
Page 8: ...1 Before External Control ME LPMSZ SR 9...
Page 16: ...2 Basics of Serial Communication RS 232 Ethernet ME LPMSZ SR 9...
Page 34: ...3 Communication Command and Function ME LPMSZ SR 9...
Page 165: ...Troubleshooting ME LPMSZ SR 9...
Page 186: ...Character Code Table ME LPMSZ SR 9...
Page 199: ...Index ME LPMSZ SR 9...
Page 202: ...202 MEMO No 9000 0063 59V ME LPMSZ SR 9...
Page 203: ...No 9000 0063 59V...
Page 204: ...Panasonic Industrial Devices SUNX Co Ltd 2013 2019 March 2019 9000 0063 59V...