Laser output measurement/correction
[Function specific to LP-M5xx / LP-M2xx / LP-Sxxx type]
*
This function is not implemented in the LP-Z series / LP-MAxx / LP-SxxxW type.
WARNING
•
Laser is radiated with the internal shutter closed. Be sure to use the protective
goggle and enclosure in case of laser leakage. Also, do not place any objects
around the radiating area.
The current power of the laser marker against the output of the laser marker at shipping is possible to be checked. After the
measurement if the power decays lower than the delivery status, the laser power setting value can be corrected.
Laser power measurement
1.
Enter a value in the “Setting Power” (Laser Power Setting)
field and press [MEASURE].
Setting Range: 12.0 to 100.0 (LP-M500/LP-S500)*
*
For the setting range of the other model, refer to “Input Setting Value by
Series” (P.296).
2.
The starting check screen is displayed.
Press [START].
The current laser power is measured.
Reference
•
For LP-M5xx-S / M2xx-S type, laser power measurement can not start without opening the laser gate. After starting the
measurement, open the laser gate by external control signals.
Refer to the “Safety / Setup / Maintenance Guide” for detail.
3.
The measurement result is indicated.
If the measured laser power is not higher than the preset low alarm limit, an
alarm message “Detected decrease of the laser power” will appear.
ME-LPMSZ-OP-7
Summary of Contents for LP-M Series
Page 11: ...1 Basic Operation Procedure ME LPMSZ OP 7 ...
Page 76: ...76 MEMO ME LPMSZ OP 7 ...
Page 77: ...2 Description of Operation Screen ME LPMSZ OP 7 ...
Page 102: ...102 Symbol ME LPMSZ OP 7 ...
Page 255: ...Troubleshooting ME LPMSZ OP 7 ...
Page 276: ...Appendix ME LPMSZ OP 7 ...
Page 304: ...Index ME LPMSZ OP 7 ...
Page 307: ...No 9000 0063 56V ...
Page 308: ... Panasonic Industrial Devices SUNX Co Ltd 2013 2019 March 2019 9000 0063 56V ...