226
Operator Adjustment Screen/Adjustment Accepted Parameters
The setting parameters that can be set on the operator's adjustment screen are selected. Refer to “2-4 Operator Adjustment
Screen” (P.85).
1
2
Description
1
Setting permission:
Check the respective boxes to make the adjustment on the operator’s adjustment screen possible.
•
X/Y Offset
•
Z Offset (LP-M/Z series only)
•
Line Speed (Except LP-SxxxW type)
•
Laser Power
•
Scan Speed
•
Laser Pulse Cycle (Except LP-SxxxW type)
•
Change File No.
•
Overwriting
•
Marking Energy (LP-M series /LP-Sxxx type only)
•
Laser Check
2
Editable Lines:
Sets the number of line possible to be edited at the edition of character setting on the operator’s adjustment
screen.
Setting Range
0 to 99 lines
Reference
•
Setting of password is useful to avoid unintentional change of setting by operator. Setting of parameters only the
specified operators can change is possible, too. Refer to “2-16-1 Display Setting (Environment 1)” (P.225) or “2-3-3
Password to Open the Setting Screen” (P.84) for the setting of password.