192
Description
3
Waiting Time (Waiting Time Adjustment) :
Adjusts the waiting time for starting radiation at the start point of each line.
Apply to all line segment.
Setting a large value improves the marking disorder.
Too large value, however, makes the marking time longer.
Setting Range
0 to 100
Initial Value
0 (LP-MA00 / LP-SxxxW type / LP-Z series)
10 (LP-M series (except LP-MA00) / LP-Sxxx type)
4
Jump (Jump adjustment) :
Adjusts the waiting time for starting radiation at the start point of the line.
It is applied only to the lines which distance to the next line is long.
Setting a large value improves the disordered lines at the start points.
Setting a larger value makes the marking time longer.
Setting Range
0 to 100
Initial Value
0
5
Pre-scan Time :
The pre-scan time adjusts the start-up and fall times of the laser beam at the start/end points. Setting the scanning
period improves the too thick marking at the start/end points.
Setting larger value makes the marking time longer.
Setting Range
0.00 to 10.00 ms
Initial Value
0.00 ms
6
Point Rad. On/Off (Point Radiation ON/OFF Adjustment) :
Adjusts the on/off timing of the radiation for “2-10-6 Point Radiation Condition” (P.181).
On time specifies the waiting time for starting radiation.
Off time specifies the waiting time for moving to the next radiation points.
Setting a larger value makes the marking time longer.
Setting Range
0.00 to 9.99 ms
Initial Value
0.00 ms
7
Laser Pulse Width (LP-Z series only) :
Specifies the laser pulse width. The narrower the pulse width sets, the higher the peak power of the laser raises,
and the device can perform the marking more sharply.
Setting Range
30 ns, 100 ns, 200 ns (LP-Z130)*
*
For the setting range of the other model, refer to “Input Setting Value by Series” (P.296).
ME-LPMSZ-OP-7
Summary of Contents for LP-M Series
Page 11: ...1 Basic Operation Procedure ME LPMSZ OP 7 ...
Page 76: ...76 MEMO ME LPMSZ OP 7 ...
Page 77: ...2 Description of Operation Screen ME LPMSZ OP 7 ...
Page 102: ...102 Symbol ME LPMSZ OP 7 ...
Page 255: ...Troubleshooting ME LPMSZ OP 7 ...
Page 276: ...Appendix ME LPMSZ OP 7 ...
Page 304: ...Index ME LPMSZ OP 7 ...
Page 307: ...No 9000 0063 56V ...
Page 308: ... Panasonic Industrial Devices SUNX Co Ltd 2013 2019 March 2019 9000 0063 56V ...