54
3. Laser Pumping Switch (with white LED): LASER
This is the switch for starting laser pumping.
LED flashes (LP-400 / LP-W series: approx. 15 sec., LP-V series: approx. 20 sec.) in white when the switch is
pressed, and it lights up when the laser irradiation becomes enabled.
4. Remote Switch (with white LED): REMOTE
This is the switch for activating communication control and I/O control. This indicator is lighted-up by pressing this
switch, and is changed into remote mode.
5. Alarm Reset Switch (with blue LED): ALARM RESET
This switch is used to reset the system when an alarm generates. LED lights up in blue when an alarm generates.
Release the cause of alarm and press this switch. Alarm can be reset from the I/O terminal, console (optional) or
monitor screen.
6. Emergency Stop Switch: EMERGENCY STOP
This switch is used to forcibly stop the laser pumping.
Push this switch at emergency or to stop the laser radiation. Turn the switch to the direction of the arrow to release it.
7. Console Connector: CONSOLE
This is the connector for console (optional).
8. USB Connector B: PC
This is the connector for connecting the attached USB cable. Connect with PC in using Laser Marker NAVI.
9. USB Connector A: USB MEDIA
This is the terminal for connecting the USB media or USB mouse.
For registering or saving data in the laser marker, connect a commercially available USB. USB media with security
features cannot be used.
You can also connect a USB mouse when setting by using a commercially available monitor.
A USB port is also mounted at the back.
Notice
•
Do not connect the USB devices other than a USB media or a USB mouse.
10. Intake Vent for Controller Air Cooling
Air inlet for cooling the controller. In this vent the filter is installed.
ME-LP400V-OP-6
Summary of Contents for LP-400 Series
Page 11: ...11 MEMO ME LP400V OP 6 ...
Page 32: ...32 1 Product Overview ME LP400V OP 6 ...
Page 58: ...2 Installation and Connection ME LP400V OP 6 ...
Page 77: ...3 Basic Operation Procedure ME LP400V OP 6 ...
Page 121: ...4 Description of Operation Screen ME LP400V OP 6 ...
Page 146: ...146 Symbol ME LP400V OP 6 ...
Page 271: ...271 MEMO ME LP400V OP 6 ...
Page 272: ...Maintenance ME LP400V OP 6 ...
Page 291: ...Troubleshooting ME LP400V OP 6 ...
Page 308: ...Appendix ME LP400V OP 6 ...
Page 328: ...Index ME LP400V OP 6 ...
Page 333: ...No 9000 0062 14V ...
Page 334: ... Panasonic Industrial Devices SUNX Co Ltd 2003 2018 July 2018 9000 0062 14V ...