125
⿎
External offset condition : OFC
Sets input conditions of “External Offset Function” to switch coordinates using I/O input.
•
Setting / Readout data of external offset condition
STX
OFC
Sub
command
[External offset]
1-byte
(Check
sum)
Delimiter
Sub command is “S” at the time of setting and “A” for response data at the time of readout.
•
Readout request of external offset condition
STX
OFC
R
(Check sum)
Delimiter
Name
Data length [byte]
Description
Remarks
External offset
1
“0”: no use
“1”: low 4-bit
“2”: low 8-bit
⿎
External offset coordinates : OFS
Sets offset coordinates used for “External Offset Function” to switch coordinates using I/O input.
•
Setting / Readout data of external offset coordinates
STX
OFS
Sub
command
[Parallel data No.] [X offset] [Y offset] [
θ
offset]
26-byte
(Check
sum)
Delimiter
Sub command is “S” at the time of setting and “A” for response data at the time of readout.
•
Readout request of external offset coordinates
STX
OFS
R
[Parallel data No.]
3-byte
(Check
sum)
Delimiter
Name
Data length
[byte]
Description
Remarks
Parallel data No.
3
“000”–“255”
The parallel data number in which offset
is set is indicated.
X offset
8
Model type*
Setting range [mm]
LP-V10
“-045.000”–“+045.000”
LP-4x0
“-055.000”–“+055.000”
LP-4x5/LP-V15
“-080.000”–“+080.000”
LP-4x1/LP-W
“-027.500”–“+027.500”
Y offset
8
θ
offset
7
“-180.00”–“+180.00” [°]
The rotation offset is indicated.
* For the detail of the model type, refer to “Target laser marker” (P.8).
ME-LP400V-EX-6
Summary of Contents for LP-400 Series
Page 12: ...1 Before External Control ME LP400V EX 6...
Page 24: ...2 Control by I O ME LP400V EX 6...
Page 56: ...3 Control by Serial Communication RS 232 Ethernet ME LP400V EX 6...
Page 141: ...Troubleshooting ME LP400V EX 6...
Page 158: ...Character Code Table ME LP400V EX 6...
Page 176: ...Index ME LP400V EX 6...
Page 179: ...No 9000 0062 17V...
Page 180: ...Panasonic Industrial Devices SUNX Co Ltd 2003 2018 July 2018 9000 0062 17V...