Problem
Cause and Solution
The orientation of the image
and sound do not match (the
voice of a person on a side of
the screen comes from the
opposite side’s speaker, etc.).
•
The speakers are not properly positioned.
→
Position speakers on either side of the display and check that the left/
right wiring is correct. If you place the display at the front of the room
and the speakers at the back, the microphone’s left/right spatial
direction may be reversed, and the orientation of the image and sound
will not match.
•
The speakers of the other party are not properly positioned.
→
Ask the other party to position speakers on either side of the display.
When the MIC position is set automatically, if the other party places the
display at the front of the room and the speakers at the back, the
microphone’s left/right spatial direction may be reversed, and the
orientation of the image and sound will not match.
•
The MIC positions set manually by the other party are incorrect.
→
Ask the other party to confirm the manual settings of their MIC positions.
When setting the MIC position manually, the left/right orientation should
match the left/right channels as viewed from the side of the main video
camera. When the MIC position is set to
"Center stereo"
, make sure
that it is placed with its connector facing the display (Page 92).
System Settings
Problem
Cause and Solution
The settings of the unit cannot
be changed.
•
A video conference call is in progress.
→
Make settings after ending the current video conference call.
•
A video conference call is incoming.
→
A dialogue box will be displayed asking whether to answer the call.
Press
[End]
to disconnect the incoming call, and then configure the
setting on the unit.
→
If a video conference call is received when editing settings on the unit,
a dialogue box will be displayed asking whether to answer the call
without saving the settings, and you will temporarily be unable to edit
the settings. To continue editing, reject the call.
If These Messages Appear
Message
Cause and Solution
Call FAILED. Please change
the encryption setting from
"On" to "Off" on the other party
and try again.
•
The encryption settings do not match those of the other party in a video
conference call.
→
Have the other party change the encryption setting from
"ON"
to
"OFF"
.
Check the Main Camera
connection.
•
A cable or cord is not properly connected.
→
Check that all cables to the unit are connected properly (Page 16).
•
The signal input from the main video camera is invalid.
→
A valid signal cannot be received from the connected main video
camera. Contact your dealer.
User Manual